testo 310 flue gas analyzer, rechargeable battery, calibration certificate for O2, CO, hPa and °C measurements, 7 in. conical sensor, silicone tube for pressure measurements, 10x particle filters, case.
Being a systems mechanic you know only too well how tough things can get when you’re working out in the field. That’s why your measuring tools need to be rugged and reliable. Like the testo 310 flue gas analyzer. Designed especially for use in the field.
AED 2,402.00
testo 310 flue gas analyzer, rechargeable battery, calibration certificate for O2, CO, hPa and °C measurements, 7 in. conical sensor, silicone tube for pressure measurements, 10x particle filters, case.
General technical data | |
---|---|
Weight | (with probe) Approx. 700 g |
Dimensions | 201 x 83 x 44 mm |
Operating temperature | -5 to +45 °C |
Display type | LCD (Liquid Crystal Display) |
Display function | Backlit 2-line display |
Power supply | Battery: 1500 mAh, mains unit 5V/1A |
Storage temperature | -20 to +50 °C |
Temperature – TC Type K (NiCr-Ni) | |
---|---|
Measuring range | -20 to +100 °C |
Accuracy | ±1 °C |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (ambient temperature)
Temperature – TC Type J (Fe-CuNi) | |
---|---|
Measuring range | 0 to +400 °C |
Accuracy | ±1 °C (0 to +100 °C)
±1.5 % of mv (> 100 °C) |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (flue gas)
Flue gas O₂ | |
---|---|
Measuring range | 0 to 21 Vol.% |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t₉₀ | 30 s |
Differential Pressure flue gas Draught – Piezoresistive | |
---|---|
Measuring range | -20 to +20 hPa |
Accuracy | ±0.03 hPa (-3.00 to +3.00 hPa)
±1.5 % of mv (Remaining Range) |
Resolution | 0.01 hPa |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range | 0 to 120 % |
Resolution | 0.1 % |
Flue gas loss (calculated) | |
---|---|
Measuring range | 0 to 99.9 % |
Resolution | 0.1 % |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range | 0 to CO₂ max (Display range) |
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t₉₀ | < 40 s |
Pressure measurement | |
---|---|
Measuring range | -40 to +40 hPa |
Accuracy | ±0.5 hPa |
Resolution | 0.1 hPa |
Flue gas CO (without H₂-compensation) | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Reaction time t₉₀ | 60 s |
Ambient CO | |
---|---|
Measuring range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Reaction time | 60 s |