SLB440-ER-1-ST

  • SLB 440 Series –
  • Compact design With integral evaluation
  • Height range 75 m (Reserve up to 90 m)
  • Safe OSSD outputs to PLe
  • Automatic start or restart interlock
  • Sturdy metal enclosure with M12 connector or cable
  • Version with heater for outdoor applications down to –30°C
  • Set-up tool and diagnostic indication

Ordering data

Product type description

SLB440-ER-1-ST

Article number (order number)

103013521

EAN (European Article Number)

4030661492339

eCl@ss number, version 12.0

27-27-27-01

eCl@ss number, version 11.0

27-27-27-01

eCl@ss number, version 9.0

27-27-27-01

ETIM number, version 7.0

EC001831

ETIM number, version 6.0

EC001831

Approvals – Standards

Certificates

TÜV

cULus

EAC

General data

Standards

EN IEC 61496-2

EN IEC 61496-1

Coding, light barrier beam

1

Enclosure material

Aluminium

Gross weight

170 g

Reaction time, maximum

22 ms

Reaction time, minimum

7 ms

General data – Features

Restart interlock (manual reset)

Yes

Beam coding available

Yes

Integral system diagnostics, status

Yes

Integral system diagnostics

Yes

Number of beams

1

Number of fail-safe digital outputs

2

Safety classification
Standards

EN ISO 13849-1

EN IEC 62061

Performance Level, up to

e

Category

4

PFH value

1.50 x 10⁻⁸ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

40 mm

Range, protection field, minimum

300 mm

Range, protection field, maximum

15,000 mm

Wave length of the sensor

880 nm

Mechanical data – Connection technique

Termination

Connector M12

Terminal connector, Recipient

Connector plug M12, 5-pole

Terminal, Connector, Transmitter

Connector plug M12, 4-pole

Mechanical data – Dimensions

Length

33 mm

Width

27.8 mm

Height

91 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-30 °C

Ambient temperature, maximum

+50 °C

Storage and transport temperature, minimum

-30 °C

Storage and transport temperature, maximum

+70 °C

Protection class

III

Electrical data

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver, maximum

5 W

Electrical power consumption of the transmitter, maximum

5 W

Length of cable, maximum

100 m

Electrical data – Safety digital outputs

Output current, (fail-safe output), maximum

0.2 A

Design of control elements

p-type