| Product type description |
PROTECT-IE-11-SK |
| Article number (order number) |
101189095 |
| EAN (European Article Number) |
4250116202232 |
| eCl@ss number, version 12.0 |
27-37-18-19 |
| eCl@ss number, version 11.0 |
27-37-18-19 |
| eCl@ss number, version 9.0 |
27-37-18-19 |
| ETIM number, version 7.0 |
EC001449 |
| ETIM number, version 6.0 |
EC001449 |
| Available until |
31.12.2024 |
| Certificates |
cULus EAC |
| Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
| Climatic stress |
EN 60068-2-78 |
| Enclosure material |
Glass-fibre reinforced thermoplastic, ventilated |
| Gross weight |
140 g |
| Stop-Category |
0 |
| Electronic Fuse |
Yes |
| Wire breakage detection |
Yes |
| Cross-circuit detection |
Yes |
| Removable Terminals |
Yes |
| Automatic reset function |
Yes |
| Earth connection detection |
Yes |
| Integral system diagnostics, general |
Yes |
| Number of auxiliary contacts |
1 |
| Number of LEDs |
5 |
| Number of normally closed (NC) |
1 |
| Number of normally open (NO) |
1 |
| Number of safety contacts |
2 |
| Safety classification |
| Standards |
EN IEC 60947-5-1 EN IEC 61508 |
| Safety classification – Relay outputs |
| Performance Level, up to |
d |
| Category |
3 |
| Diagnostic Coverage (DC) Level |
60 % |
| PFH value |
2.00 x 10⁻⁷ /h |
| Notice |
for max. 36,500 switching cycles/year and max. 60% contact load |
| Safety Integrity Level (SIL), suitable for applications in |
2 |
| Mission time |
20 Year(s) |
| Common Cause Failure (CCF), minimum |
65 |
| Mechanical life, minimum |
10,000,000 Operations |
| Mounting |
Snaps onto standard DIN rail to EN 60715 |
| Termination |
Screw connection, plug-in |
| Terminal designations |
IEC/EN 60947-1 |
| Cable section, minimum |
0.14 mm² |
| Cable section, maximum |
1.5 mm² |
| Width |
48 mm |
| Height |
126 mm |
| Depth |
61 mm |
| Degree of protection of the enclosure |
IP20 |
| Degree of protection of the mounting space |
IP20 |
| Degree of protection of clips or terminals |
IP20 |
| Ambient temperature, minimum |
-25 °C |
| Ambient temperature, maximum |
+55 °C |
| Storage and transport temperature, minimum |
-40 °C |
| Storage and transport temperature, maximum |
+85 °C |
| Resistance to vibrations |
10…55 Hz, Amplitude 0.35 mm, ± 15 % |
| Restistance to shock |
30 g / 11 ms |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Overvoltage category |
III |
| Degree of pollution |
2 |
| Rated operating voltage |
24 VDC -15% / +20%, residual ripple max. 10 % |
| Rated AC voltage for controls at DC minimum |
20.4 VDC |
| Rated control voltage at DC, maximum |
28.8 VDC |
| Electrical power consumption |
1.7 W |
| Input resistance at Ue |
2,900 Ω |
| Contact resistance, maximum |
0.1 Ω |
| Note (Contact resistance) |
in new state |
| Drop-out delay in case of “emergency stop”, maximum |
20 ms |
| Pull-in delay at automatic start, maximum |
20 ms |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
2 A |
| Switching capacity, minimum |
10 VDC |
| Switching capacity, minimum |
10 mA |
| Switching capacity, maximum |
24 VAC |
| Switching capacity, maximum |
2 A |
| Input signal, HIGH Signal “1” |
19 – 28,8 VDC |
| Input signal, LOW Signal “0” |
0 – 1 VDC |
| Conduction resistance, maximum |
40 Ω |
| Voltage, Utilisation category DC-12 |
24 VDC |
| Current, Utilisation category DC-12 |
0.1 A |
| Switching capacity, maximum |
24 VDC |
| Switching capacity, maximum |
0.1 A |
| EMC rating |
EMC-Directive |
| Indicated operating states |
Position relay K2 Position relay K1 Position relay K3 Position relay K3 |