Enviro-LOGO

Oil-resistant Limit Switch D4ER-[]N

No Cutting Oil Ingress by Any Path The Strongest Material Cables with Fluororesin Sheaths

The results of a thorough analysis of the ingress paths of cutting oil show that the deterioration of cable sheaths is a large factor. The cable sheaths of OMRON’s Oil-resistant Components are made from fluororesin materials to provide maximum protection against the deterioration with a unique new concept. The result is an oil resistance impregnable to even highly aggressive cutting oils.

Approved Standards

 

Agency Standard File No. Approved models
TÜV Rheinland EN 60947-5-1 R9551015, J9951016 Ask your OMRON representative
for information on approved models.
CCC
UL

 

Ratings

 

Rated
voltage
Standard load Micro load
Non-inductive load (A) Inductive load (A) Non-inductive load (A)
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
8 VDC
14 VDC
30 VDC
1
1
1


1
1
1


0.1
0.1
0.1

 

 

Minimum
applicable load
Standard load Micro load
160 mA at 5 VDC 1 mA at 5 VDC

 

 

Inrush current NC 10 A max.
NO 10 A max.

 

Note: 1. The above current ratings are for a standard current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.

Approved Standard Ratings

TÜV (EN 60947-5-1)

D4ER-[]N Specifications 7

 

Model Applicable category
and ratings
Thermal current
(Ithe)
I II III
1
2
[]
[]
21/22
21/22
DC-12 1 A/30 VDC
DC-12 0.1 A/30 VDC
1A
0.1A

 

Note: 1. []:Actuator variation of item II
2. DC-12 1 A/30 VDC means as follows:
Applicable category: DC-12
Rated operating current (Ie): 1 A
Rated operating voltage (Ue): 30 VDC

Characteristics (Standard Load Model and Micro Load Model)

 

Degree of protection IP67 (IEC 60529) and IP67G (JIS C 0920 Annex 1) *1
Passed OMRON’s Oil-resistant Component Evaluation Standards *2
(Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.)
Durability Mechanical 4,000,000 operations min.
Electrical 500,000 operations min.
(Standard load: 1 A at 30 VDC, resistive load/Micro load: 0.1 A at 30 VDC,
esistive load)
4,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm/sec to 0.5 m/sec
Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC) *3
Contact resistance Standard load: D4ER-1[][][]N[]: 15 mΩ max.
(initial value for the built-in switch whentested alone)
Micro load: D4ER-2[][][]N[]: 50 mΩ max.
(initial value for the built-in switch whentested alone)
Dielectric
strength
Between terminals of
same polarity
1,000 VAC, 50/60 Hz for 1 min
Between each
terminal and
noncurrent-carrying
metal part
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV
(EN 60947-5-1)
Rated insulation voltage (Ui) 250 V
Pollution degree
(operating environment)
3 (EN 60947-5-1)
Short-circuit protective device
(SCPD)
10 A fuse (type gG or type gI, IEC 60269 approved)
Conditional short-circuit current 100 A (EN 60947-5-1)
Conventional enclosed
thermal current (Ithe)
5 A (EN 60947-5-1)
Protection against electric shock Class II (grounding not required with double insulation)
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Destruction 1,000 m/s2 max. (IEC 68-2-27)
Malfunction 300 m/s2 max. (IEC 68-2-27)
Ambient operating
temperature/Ambient storage temperature
5°C to 70°C (with no icing or condensation)
Ambient operating humidity 35% to 95%RH (with no condensation)
Weight (in case of roller plunger)
Cable type (2 m): Approx. 140 g
Pre-wired Connector type: Approx. 103 g