Enviro-LOGO

Small Sealed Switch D4E-[]N

• Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action and long life expectancy.

• Protection cover protects the built-in switch from dust and oil. Plunger incorporates a tough seal cap that lasts for a long time.

• One touch connector eliminates need for tedious wiring operations and reduces downtime for wiring and maintenance (models with standard, easy-to-use screw terminals are also available).

• Minute load model with gold cladding is optimal for electronic control.

• Molded terminal types as well as molded terminal types with operating indicator lamps are available for screw terminal systems.

• Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for Information on approved models.)

• No difference in mounting pitch and characteristics between D4E-[]N and D4E models.

Approved Standards

 

Agency Standard File No. Approved models
UL UL508 E76675 D4E-[][]20N Switches only except for Indicator-
equipped Switches
CSA CSA C22.2 No. 14 LR45746 D4E-[][]20N Switches only except for Indicator-
equipped Switches
TÜV Rheinland EN60947-5-1 R9551015 Ask your OMRON representative for information on
approved models.
CCC (CQC) GB/T14048.5 Contact your OMRON
representative for details.
Ask your OMRON representative for information on
approved models.

 

Ratings

 

Rated voltage Standard load Micro load
Non-inductive load (A) Inductive load (A) Non-inductive load (A)
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5 (1)
5 (1)
1.5 (1)
1.5 (1)
3 (1)
3 (1)
2 (1)
1
1 (1)
0.5
0.1
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5 (1)
5 (1)
5 (1)
0.5
0.25




1.5 (1)
1.5 (1)
1.5 (1)
0.05
0.03




0.1
0.1
0.1

 

 

Minimum applicable load Standard load Micro load
160 mA at 5 VDC 1 mA at 5 VDC

 

 

Inrush current NC 10 A max.
NO 10 A max.

 

 

Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.

 

Approved Standard Ratings

UL/CSA
A300

 

Voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 V
240 V
10 A 60 A
30 A
6 A
3 A
7,200 720

 

TÜV (EN60947-5-1), CCC (GB/T14048.5)

D4E-[]N Specifications 8

 

Model Applicable category and ratings Thermal current
(Ithe)
Indicator
I II III IV
1 [] 00 AC-14 0.5 A/125 VAC 5 A
1 [] 10 DC-12 0.5 A/30 VDC 5 A
1 [] 20, 21, 22 AC-15 2A/250 VAC
DC-12 2A/48 VDC
5 A
1 [] 23, 24 L AC-15 2A/250 VAC 5 A Neon lamp
1 [] 23, 24 L1 DC-12 2A/12 VDC 5 A LED
1 [] 23, 24 L2 DC-12 2A/24 VDC 5 A LED
1 [] 23, 24 L3 DC-12 2A/48 VDC 5 A LED
2 [] 00 AC-14 0.1A/125 VAC 0.5 A
2 [] 10 DC-12 0.1A/30 VDC 0.5 A
2 [] 20, 21, 22 AC-14 0.1A/125 VAC
DC-12 0.1A/48 VDC
0.5 A
2 [] 23, 24 L AC-14 0.1A/125 VAC 0.5 A Neon lamp
2 [] 23, 24 L1 DC-12 0.1A/12 VDC 0.5 A LED
2 [] 23, 24 L2 DC-12 0.1A/24 VDC 0.5 A LED
2 [] 23, 24 L3 DC-12 0.1A/48 VDC 0.5 A LED

 

 

Note: 1. []:Actuator variation of item II
2. AC-14 0.5 A/125 VAC means as follows:
3. Applicable category: AC-14
Rated operating current (Ie): 0.5 A
Rated operating voltage (Ue): 125 VAC

 

Characteristics

 

Degree of protection IP67
Durability * Mechanical 10,000,000 operations min.
Electrical 500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm/sec to 0.5 m/sec
Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value for the built-in switch when tested alone)
Dielectric strength Between terminals of same
polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and
non-current-carrying metal
part
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui) 250V
Pollution degree (operating environment) 3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC60269 approved)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 5 A (EN60947-5-1)
Protection against electric shock Class II (grounding not required with double insulation)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature -10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 86 g (in case of roller plunger)