• Easy setting with thumbwheel switches.
• A draw-out construction enables maintenance without rewiring.
• Models with 2-, 4-, 6-, or 8-digit displays are also available.
• Total Counter models are also Available..
Operating method | Incrementing and decrementing (selectable with DIP switch) | |||
---|---|---|---|---|
Mounting method | Flush mounting | |||
Operation modes | N, F, C, R, K, P, Q (selectable with rotary DIP switch) | |||
Input signal method (Count and reset inputs) |
Contact and transistor input voltage (H and L) | |||
Control output | 1-stage counters: Contact (SPDT) and transistor output (H and L output switchable) 2-stage counters: Contact (SPST-NO) and transistor output (H and L output switchable) |
|||
Set value read | Continuous mode | |||
Memory backup | No | Yes/No (Selectable using DIP switch) | ||
Display | Yes (10-mm high 7-segment LED, Up indicator) |
Yes (10-mm high 7-segment LED, Up indicator) |
||
Models | 2 digits | 1 stage | H7AN-2D | H7AN-2DM |
4 digits | 1 stage | H7AN-4D | H7AN-4DM | |
2 stages | H7AN-W4D | H7AN-W4DM |
Operating method | Reversible (selectable with rotary DIP switch) between 0 and the set value Incrementing/decrementing A/D (command inputs) Incrementing/decrementing B/E (individual inputs) Incrementing/decrementing C/F (phase difference inputs) |
|||
---|---|---|---|---|
Mounting method | Flush mounting | |||
Operation modes | N, F, C, R, K, P, Q (selectable with rotary DIP switch) | |||
Input signal method (Count, reset input) |
Contact and transistor input voltage (H and L) | |||
Control output | 1-stage counters: Contact (SPDT) and transistor output (H and L output switchable) 2-stage counters: Contact (SPST-NO) and transistor output (H and L output switchable) |
|||
Set value read | Continuous mode | |||
Memory backup | No | Yes/No (Selectable using DIP switch) | ||
Display | Yes (10-mm high 7-segment LED, Up indicator) | |||
Models | 2 digits | 1 stage | H7AN-E2D | H7AN-E2DM |
4 digits | 1 stage | H7AN-E4D | H7AN-E4DM | |
2 stages | H7AN-WE4D | H7AN-WE4DM |
Operating method | Incrementing, decrementing, and reversible (UP/DOWN A to F) (selectable with rotary DIP switch) |
|||
---|---|---|---|---|
Mounting method | Flush mounting | |||
Operation modes | N, F, C, R, K, P, Q (selectable with rotary DIP switch) | |||
Input signal method (Count, reset input) |
Contact and transistor input voltage (H and L) | |||
Control output | 1-stage counters: Contact (SPDT) and transistor output (H and L output switchable) 2-stage counters: Contact (SPST-NO) and transistor output (H and L output switchable) |
|||
Set value read | Continuous mode, Reset mode (selectable) | |||
Memory backup | No | Yes/No (Selectable using DIP switch) | ||
Display | Yes (8-mm high 7-segment LED, Up indicator) | |||
Models | 6 digits | 1 stage | H7AN-R6D | H7AN-R6DM |
2 stage | H7AN-RW6D | H7AN-RW6DM | ||
8 digits | 1 stages | H7AN-R8D | H7AN-R8DM |
Operating method | Incrementing and decrementing (selectable with DIP switch) | ||
---|---|---|---|
Mounting method | Flush mounting | ||
Input signal method (Count, reset input) | Contact and transistor input voltage (H and L) | ||
Memory backup | No | Yes/No (Selectable using DIP switch) | |
Display | Yes (10-mm high 7-segment LED) | ||
Models | 4 digits | H7AN-T4 | H7AN-T4M |
Operating method | Reversible (selectable with rotary DIP switch) between 0 and the full scale Incrementing/decrementing A/D (command inputs) Incrementing/decrementing B/E (individual inputs) Incrementing/decrementing C/F (phase difference inputs) |
|
---|---|---|
Mounting method | Flush mounting | |
Input signal method (Count, reset input) |
Contact and transistor input voltage (H and L) | |
Memory backup | Yes/No (Selectable using DIP switch) | |
Display | Yes (10-mm high 7-segment LED) | |
Models | 4 digits | H7AN-ET4M |
Operating method | Incrementing, decrementing, and reversible (UP/DOWN A to F) | ||
---|---|---|---|
Mounting method | Flush mounting | ||
Input signal method (Count, reset input) | Contact and transistor input voltage (H and L) | ||
Memory backup | No | Yes/No (Selectable using DIP switch) | |
Display | Yes (8-mm high 7-segment LED) | ||
Models | 6 digits | H7AN-RT6 | H7AN-RT6M |
8 digits | — | H7AN-RT8M |
Rated supply voltage | 100 to 240 VAC, 50/60 Hz (common use); 12 to 24, 48, 100 VDC *1 |
---|---|
Operating voltage range | 85% to 110% of rated voltage |
Power consumption | Approx. 10 VA (240 VAC at 50 Hz); Approx. 5 W (at 24 VDC) *2 |
Max. counting speed of CP1 and CP2 |
2-digit counters: 30 Hz 4-digit counters: 30 Hz or 5 kHz 6- or 8-digit counters: 30 Hz or 5 kHz Minimum signal width (with ON/OFF ratio of 1:1): 30 Hz: 16.7 ms, 5 kHz: 0.1 ms H: 4.5 to 30 VDC, L: 0 to 2 VDC |
Reset | Power supply reset (except for H7AN Counter with suffix “-M”): Minimum power-OFF time: 0.5 s with a reset time of 0.05 s after power-ON. External, manual, reset signal time: 0.02 s Reset time after completion of reset signal: 0.05 s Automatic reset *3 |
Control output | Contacts: 3 A at 250 VAC, resistive load (cosφ = 1) No-contacts: 100 mA max. at 30 VDC max., open collector |
Min. applicable load | 10 mA at 5 VDC (p level reference value) |
External power supply | 80 mA, 12 VDC ±10% (contains 5% ripple max.) |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | 35% to 85% |
Case color | Light gray (Munsell 5Y7/1) |
Insulation resistance | 100 MW min. (at 500 VDC) (between current-carrying terminal and exposed non-current- carrying metal parts, and between non-continuous contacts) |
---|---|
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and exposed non- current carrying metal parts) 750 VAC, 50/60 Hz for 1 min (between non-continuous contacts) |
Impulse withstand voltage | 6 kV (between power terminals), 6 kV (between current-carrying terminal and exposed non-current-carrying metal parts) |
Noise immunity | ±2 kV between power terminals (±480 V for models with 12 to 24 VDC) ±500 V between input terminals Square-wave noise by noise simulator (pulse width: 100 ns, 1-ns rise) |
Vibration resistance | Destruction:10 to 55 Hz, 0.75-mm double amplitude Malfunction:10 to 55 Hz, 0.5-mm double amplitude |
Shock resistance | Destruction: 300 m/s2 Malfunction: 100 m/s2 |
Life expectancy | Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) |
Memory backup storage method * |
Non-volatile memory (Number of writes: 1 million times, Data retention: 10 years) |
Weight | Approx. 360 g |
* This applies only to the models ending with -M.
Approved safety standards | UL508/CSA C22.2 No. 14 EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II |
---|---|
EMC | (EMI) EN61326 Emission Enclosure: EN 55011 Group 1 class A Emission AC mains: EN 55011 Group 1 class A (EMS) EN61326 Immunity ESD: EN 61000-4-2 Immunity RF-interference: EN 61000-4-3 Immunity Conducted Disturbance: EN 61000-4-6 Immunity Burst: EN 61000-4-4 Immunity Surge: EN 61000-4-5 Immunity Voltage Dip/Interruption: EN 61000-4-11 |