Contact resistance *1 |
100 mΩ max. |
Operating time *2 |
50 ms max. |
Release time *2 |
50 ms max. |
Must operate voltage |
80% max. |
Must release voltage |
10% min. |
Maximum operating
frequency |
Mechanical |
18,000 operations/h |
Rated load |
1,800 operations/h |
Insulation resistance *3 |
100 MΩ min. |
Dielectric strength *4 *5 |
Between coil and contacts:
Between coil and pole 3 or coil and pole 4: 4,000 VAC, 50/60 Hz for 1 min
Other than the above:2,500 VAC, 50/60 Hz for 1 min
Between different poles:
Between pole 1, 3, or 5 and pole 2, 4, or 6: 4,000 VAC, 50/60 Hz for 1 min
Other than the above:2,500 VAC, 50/60 Hz for 1 min
Between contacts of same polarity:1,500 VAC, 50/60 Hz for 1 min |
Vibration resistance |
Destruction |
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
Malfunction |
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) |
Shock resistance |
Destruction |
1,000 m/s2 |
Malfunction |
100 m/s2 |
Durability *6 |
Mechanical |
10,000,000 operations min. (at approx. 18,000 operations/h) |
Electrical |
100,000 operations min. (at the rated load and approx. 1,800 operations/h) |
Inductive load
switching capability *7
(IEC60947-5-1) |
NO Contact |
AC15 AC240V 5A
DC13 DC24V 2A |
NC Contact |
AC15 AC240V 3A
DC13 DC24V 2A |
Failure rate (P level)
(reference value *8) |
5 VDC, 1 mA |
Ambient operating temperature |
-25 to 70°C (with no icing or condensation) |
Ambient operating humidity |
5% to 85% |
Weight |
Approx. 65 g |
Note: 1. The above values are initial values.
2. Performance characteristics are based on a coil temparature of 23°C.
*1. Measurement conditions: 5 VDC, 10 mA, voltage drop method.
*2. Measurement conditions: Rated voltage operation
Ambient operating temperature: 23°C
Contact bounce time is not included.
*3. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric
strength was measured.
*4. When using a P7S Socket, the dielectric strength between coil and contacts and between different poles is 2,000 VAC,
50/60 Hz for 1 min.
*5. The coil refers to terminals 0-1, pole 1 refers to terminals 13−14, pole 2 refers to terminals 23−24, pole 3 refers to
terminals 33−34, pole 4 refers to terminals 41−42 or 43−44, pole 5 refers to terminals 51−52, and pole 6 refers to
terminals 61−62.
*6. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
*7. AC15: cosφ = 0.3, DC13: L/R = 96-ms
*8. The failure rate is based on an operating frequency of 60 operations/min.