G2RV-SR

• Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel.

• Realized opening and closing ability with one pole 6 A slim shape.

• Micro load products for one pole 50 mA using Au-plated contacts for small load switching also available.

• Since G2RV is a transparent case, confirming the state of the contact with the naked eye is possible, and easy to confirm abnormality on-site (installed location).

• Screw terminal is also stocked to meet the screw type needs.

• Mounted relay uses plug-in terminals that are difficult to bend when exchanging.

• G3RV-SR featuring a solid state relay similar in shape to G2RV-SR also available.

• Coil surge absorption circuit is equipped as standard.

Ratings

Coil ratings

 

Rated input
voltage
Rated current Must
operate
voltage
Must
release
voltage
Power consumption Maximum
allowable
voltage
AC DC Percentage of
the rated voltage
AC (VA) DC (mW) Percentage
of the rated
voltage
50 Hz 60 Hz
12 VDC 27.9 mA 80% max.* 10% min. Approx. 300 mW 110%
24 VDC 13.5 mA Approx. 300 mW
24 VAC/VDC 12.5 mA 12.6 mA 12.6 mA Approx. 0.5 VA Approx. 300 mW
48 VAC/VDC 5.9 mA 6.1 mA 5.2 mA Approx. 0.4 VA Approx. 250 mW
100 VAC 5.9 mA 6.0 mA Approx. 0.8 VA
110 VAC 5.9 mA 5.9 mA Approx. 0.8 VA
200 VAC 6.6 mA 7.6 mA Approx. 1.7 VA
230 VAC 7.3 mA 8.4 mA Approx. 1.7 VA

 

 

Note: The operating characteristics are measured at ambient temperature of 23°C.
* Operating voltage will be, for mounting in the upside down direction, 85% max.
(Upside down: Direction in which the mechanical indicator faces down)

 

Contact ratings

 

Item Standard
(G2RV-SR700, 500, 701, 501)
For microloads
(G2RV-SR700-AP,
500-AP) *2
Contact configuration SPDT
Load Resistive load
(cosφ=1)
Inductive load
(cosφ=0.4, L/R=7ms)
Resistive load
(cosφ=1)
Rated load 6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
50 mA at 30 VAC
50 mA at 36 VDC
Rated carry current 6 A 50 mA
Maximum switching voltage 440 VAC, 125 VDC 30 VAC, 36 VDC
Maximum switching current 6 A 50 mA
Maximum switching power 1,500 VA
180 W
500 VA
60 W
Failure rate P value
(reference value) *1
10 mA at 5 VDC 1 mA at 100 mVDC

 

*1. P level: λ60=0.1×10-6/times
This value is the value in switching frequency 120 operations/min.
*2. If the Au plating layer is destroyed, the number will be the same as the standard type.

Characteristics

 

Item Standard
(G2RV-SR700, 500, 701, 501)
For microloads
(G2RV-SR700-AP, 500-AP)
Contact resistance *1 100 mΩ max.
Operate (Set) time *1 20 ms max.
Release time *1 AC, AC/DC: 40 ms max.
DC: 20 ms max.
Maximum operating
frequency
Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Vibration resistance *2 Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance *2 Destruction: 1,000 m/s2
Malfunction: Energized 200m/s2, Non-energized 100m/s2
Endurance *1 Mechanical 5,000,000 operations min.
Electrical NO contact: 70,000 operations min.
NC contact: 50,000 operations min.
5,000,000 operations min.
Ambient operating
temperature
Operating: -40 to +55°C (with no icing or condensation)
Ambient operating
humidity
Operating: 5 to 85% RH
Weight Approx. 30 g
Contact material Ag alloy Ag alloy + Au plating

 

Note: Above values are initial values.
*1. Value is at ambient temperature of 23°C.
*2. Value when the end plate is used.

Approved standards

UL (File No.E41643)

 

Model Contact form Operation coil ratings Contact ratings Operations
G2RV-SR series SPDT 12 to 48 VDC
24 to 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive load)*
6,000

 

* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).

G2RV-SR Specifications 10

TÜV (File No.R50327609, EN 61810-1)

 

Model Contact form Operation coil ratings Contact ratings Operations
G2RV-SR series SPDT 12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive load)*
50,000
50,000
6,000

 

* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).

G2RV-SR Specifications 12

Lloyd’s (File No.07/10020)

 

Model Contact form Operation coil ratings Contact ratings
G2RV-SR500
G2RV-SR700
SPDT 12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
2 A at 30 VDC (L/R=7ms)
G2RV-SR501
G2RV-SR701
SPDT 12, 24 VDC
24 VAC/VDC
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
2 A at 30 VDC (L/R=7ms)
G2RV-SR500-AP
G2RV-SR700-AP
SPDT 12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
0.05 A at 30 VAC (Resistive load)
0.05 A at 36 VDC (Resistive load)