G2R-[]-S (S)

• Reduces wiring work by 60% when combined with the P2RF-[]-PU Push-In Plus Socket

(according to actual OMRON measurements).

• Lockable test button models available.

• Built-in mechanical operation indicator.

• Provided with nameplate.

• AC type is equipped with a coil-disconnection self-diagnostic function (LED type).

• High switching power (1-pole: 10 A).

Coil Ratings

 

Rated voltage Rated current* Coil
resistance
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
50 Hz 60 Hz Armature
OFF
Armature
ON
% of rated voltage
AC 24 V 43.5 mA 37.4 mA 253 Ω 0.81 1.55 80% max. 30% max. 110% 0.9 VA at 60 Hz
48 V 21.8 mA 18.8 mA 1,040 Ω 3.12 6.17
110 V 9.5 mA 8.2 mA 5,566 Ω 13.33 26.83
120 V 8.6 mA 7.5 mA 7,286 Ω 16.13 32.46
230 V 4.4 mA 3.8 mA 27,172 Ω 72.68 143.9
240 V 4.2 mA 3.7 mA 27,800 Ω 90.58 182.34

 

 

Rated voltage Rated current* Coil
resistance
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
Armature
OFF
Armature
ON
% of rated voltage
DC 6 V 87.0 mA 69 Ω 0.25 0.48 70% max. 15% min. 110% 0.53 W
12 V 43.2 mA 278 Ω 0.98 2.35
24 V 21.6 mA 1,113 Ω 3.6 8.25
48 V 11.4 mA 4,220 Ω 15.2 29.82

 

Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of
+15%/-20% for the AC rated current and ±10% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil.
It is not the maximum voltage that can be applied continuously.

Contact Ratings

 

Number of poles 1 pole 2 poles
Load Resistive load
(cosΦ = 1)
Inductive load
(cosΦ = 0.4; L/R = 7 ms)
Resistive load
(cosΦ = 1)
Inductive load
(cosΦ = 0.4; L/R = 7 ms)
Rated load 10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC;
3 A at 30 VDC
Rated carry current 10 A 5 A
Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 10 A 5 A
Max. switching power 2,500 VA, 300 W 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W
Failure rate (reference value) * 100 mA at 5 VDC 10 mA at 5 VDC

 

Note: P level: λ60 = 0.1 x 10-6/operation
*This value was measured at a switching frequency of 120 operations per minute.

Characteristics

 

Item 1 pole 2 poles
Contact configration SPDT
Contact structure Single
Contact resistance 100 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength * 5,000 VAC, 50/60 Hz for 1 min between coil and
contacts;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized
Endurance Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Ambient temperature Operating: -40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 20 g

 

Note: Values in the above table are the initial values.
*These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets.

Approved Standards

UL 508 (File No. E41643)

 

Model Contact form Coil ratings Contact ratings Operations
G2R-1-S (S) SPDT 5 to 110 VDC
6 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
100 × 103
TV-3 (NO contact only) 25 × 103
G2R-2-S (S) DPDT 5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
100 × 103
TV-3 (NO contact only) 25 × 103

 

CSA 22.2 No.0, No.14 (File No. LR31928)

 

Model Contact form Coil ratings Contact ratings Operations
G2R-1-S (S) SPDT 5 to 110 VDC
6 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
100 × 103
TV-3 (NO contact only) 25 × 103
G2R-2-S (S) DPDT 5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
100 × 103
TV-3 (NO contact only) 25 × 103

 

IEC/VDE (Certificate No. 40015012 EN 61810-1)

 

Contact form Coil ratings Contact ratings Operations
1 pole 6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
100 × 103
2 poles 6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
100 × 103

 

LR

 

Number of poles Coil ratings Contact ratings Operations
1 pole 5 to 110 VDC
6 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
100 × 103
2 poles 5 to 110 VDC
6 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
100 × 103

 

Accessories (Order Separately)

Socket Characteristics

 

Model Rated
carry
current
Dielectric strength Insulation
resistance*
Remarks
P2RF-05-PU 10 A Between contact terminals of same polarity: 1,000 VAC for
1 min
1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
P2RF-08-PU 6 A Between contact terminals of different polarity: 3,000 VAC
for 1 min
1,000 MΩ min.
Between contact terminals of same polarity: 1,000 VAC for
1 min
Between coil and contact terminals: 4,000 VAC for 1 min
P2RFZ-05(-E) 10 A Between contact terminals of same polarity: 1,000 VAC for
1 min
1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
P2RFZ-08(-E) 6 A Between contact terminals of different polarity: 3,000 VAC
for 1 min
1,000 MΩ min.
Between contact terminals of same polarity: 1,000 VAC for
1 min
Between coil and contact terminals: 4,000 VAC for 1 min
P2RF-05 10 A Between contact terminals of same polarity: 1,000 VAC for
1 min
1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
P2RF-08 5 A Between contact terminals of different polarity: 3,000 VAC
for 1 min
1,000 MΩ min.
Between contact terminals of same polarity: 1,000 VAC for
1 min
Between coil and contact terminals: 4,000 VAC for 1 min
P2R-05P 10 A Between contact terminals of same polarity: 1,000 VAC for
1 min
1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
P2R-08P 5 A Between contact terminals of different polarity: 3,000 VAC
for 1 min
1,000 MΩ min.
Between contact terminals of same polarity: 1,000 VAC for
1 min
Between coil and contact terminals: 4,000 VAC for 1 min
P2R-057P 10 A Between contact terminals of same polarity: 1,000 VAC for
1 min
1,000 MΩ min.
Between coil and contact terminals: 5,000 VAC for 1 min
P2R-087P 5 A Between contact terminals of different polarity: 3,000 VAC
for 1 min
1,000 MΩ min.
Between contact terminals of same polarity: 1,000 VAC for
1 min
Between coil and contact terminals: 5,000 VAC for 1 min
P2R-05A 10 A Between contact terminals of same polarity: 1,000 VAC for
1 min
1,000 MΩ min.
Between ground terminals: 1,500 VAC for 1 min
Between coil and contact terminals: 4,000 VAC for 1 min
P2R-08A 5 A Between contact terminals of different polarity: 3,000 VAC
for 1 min
1,000 MΩ min.
Between contact terminals of same polarity: 1,000 VAC for
1 min
Between ground terminals: 1,500 VAC for 1 min
Between coil and contact terminals: 4,000 VAC for 1 min