Enviro-LOGO

D4JL, D4JL-SK40

Plastic Guard Lock Safety-door Switches Holding Force of 3,000 N

Suitable for large, heavy doors.

Wide variations to protect workers who enter hazardous areas.

Models with Trapped Keys (mechanical lock models only)
As long as a person has the trapped key when he enters a hazardous area, he does not have to worry about somebody locking the door and trapping him inside.
The door can be opened only by supplying power to the solenoid and then turning the trapped key to unlock the D4JL.
There are thirty different types of trapped keys available for use in applications with adjacent hazardous areas.

Models with Rear Release Buttons
A rear release button allows the door to be unlocked from inside a hazardous area in an emergency.

Special Slide Key
A special Slide Key shortens the lead time for mounting design.
The padlock that can be attached to the disable-prevention cover prevents other workers from restarting machines.
(See Data Sheet for details.)

 

Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
• EN ISO 14119
• EN 60204-1
• GS-ET-19

Certified Standards

 

Certification body Standard File No.
TÜV SÜD EN 60947-5-1
(certified direct opening)
Consult your OMRON representative for details.
UL *1 UL 508, CSA C22.2 No.14 E76675
CQC (CCC) GB/T 14048.5 Consult your OMRON representative for details.
KOSHA *2 EN60947-5-1 Consult your OMRON representative for details.

 

*1. CSA C22.2 No. 14 was certified by UL.
*2. Only certain models have been certified.

Certified Standard Ratings

TÜV (EN 60947-5-1)

 

Utilization category AC-15 DC-13
Rated operating current (Ie) 3 A 0.27 A
Rated operating voltage (Ue) 240 V 250 V

 

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
into the Switch.

 

UL/CSA (UL 508, CSA C22.2 No. 14)

A300 (between terminals 12 and 41)

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
240 VAC 30 3

 

A300 (between all other terminals)

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
240 VAC 3 A 30 3 7,200 720

 

Q300

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
125 VDC
250 VDC
2.5 A 0.55
0.27
0.55
0.27
69 69

 

Solenoid Coil Characteristics

 

Type 24 VDC
Rated operating voltage (100% ED) 24 VDC +10%, -15%
Current consumption Approx. 200 mA
Insulation Class Class B (130°C max.)

 

Indicator Characteristics

 

Type LED
Rated voltage 24 VDC 24 VDC
Current consumption Approx. 1 mA Approx. 8 mA
Color (LED) Orange Green

 

Characteristics

 

Interlock type Type 2 (EN ISO 14119)
Coding level Low level coded (EN ISO 14119)
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 1,000,000 operations min.
Trapped key 10,000 operations min.
Rear release
button
D4JL-[][]FA-[]7-[]: 3,000 operations min.
D4JL-[][]FA-[]8-01-SJ: 500 operations min.
Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3
Operating speed 0.05 to 0.5 m/s
Operating frequency 30 operations/minute max.
Direct opening force *4 60 N min. (EN60947-5-1)
Direct opening travel *4 15 mm min. (EN60947-5-1)
Holding force (Fzh) *5 3,000 N min.
Contact resistance 25 mΩ max. (per contact)
Minimum applicable load *6 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui) 300 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation) 1611_sp_7_1
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse
withstand
voltage (Uimp)
(EN60947-5-1)
Between terminals of
same polarity
2.5 kV
Between terminals of
different polarity
4 kV
Between other
terminals and
non-current carrying
metallic parts
6 kV
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact gap 2 × 2 mm min.
Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude
Shock resistance Destruction 1,000 m/s2 min.
Malfunction 80 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1) *7
Conventional free air thermal current (Ith) 10 A (between terminals 12 and 41),
3 A (between all other terminals) (EN60947-5-1)
Ambient operating temperature -10 to +55°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 650 g (D4JL-4NFA-C7-01)