AZ 15 ZVRK-M16

Article number: 101153619

  • 3 cable entries M 16 x 1.5
  • plastic housing
  • double insulated
  • long life span
  • 52mm x 75mm x 30mm
  • Universal coding
  • large connection room
  • high contact security at low currents
  • Slotted holes for adjustment, round holes for fixing
  • insensitive to pollution

order data

Product type designation

AZ 15 ZVRK-M16

Article number (order number)

101153619

EAN (European Article Number)

4030661169354

eCl@ss number, version 12.0

27-27-26-02

eCl@ss number, version 11.0

27-27-26-02

eCl@ss number, version 9.0

27-27-26-02

ETIM number, version 7.0

EC002592

ETIM number, version 6.0

EC002592

Approvals – Regulations

certificates

MOT

cULus

CCC

General data

regulations

EN ISO 13849-1

EN ISO 14119

ENIEC 60947-5-1

Coding level according to EN ISO 14119

small amount

working principle

electromechanical

Material of the housing

Plastic, glass fiber reinforced thermoplastic, self-extinguishing

Material of contacts, electrical

Silver

gross weight

100 g

General data – properties

Increased detent force

Yes

Usable for elevators

Yes

Number of cable penetrations

3

Number of safety contacts

1

safety consideration

regulations

EN ISO 13849-1

service life

20 years

Safety Consideration – Safety Outputs

10D normally closed (NC)

2,000,000 switching cycles

mechanical data

Mechanical life, minimum

1,000,000 switching cycles

cogging force

30N

positive opening travel

8mm

Positive opening force per NC contact, minimum

10N

Actuation speed, maximum

2m/s

Mechanical data – connection technology

connection type

screw terminals

cable entry

3x M16x1.5

Connection cross-section, minimum

0.25mm²

Connection cross-section, maximum

2.5mm²

Note (connection cross-section)

All information including ferrules.

Mechanical data – dimensions

length of the sensor

30mm

width of the sensor

52mm

height of the sensor

75mm

Environmental conditions

Degree of protection

IP67

ambient temperature, min

-30℃

ambient temperature, max

+80°C

Storage and transport temperature, minimum

-40℃

Storage and transport temperature, maximum

+85°C

Permissible installation height above sea level, maximum

2,000m

storage and transport temperature

-40 … +85 °C

Ambient conditions – insulation values

Rated insulation voltage U i

500v

Rated impulse withstand voltage U imp

6kV

overvoltage category

III

degree of pollution

3

electrical data

Thermal continuous current

10A

Conditional rated short-circuit current

1,000A

switching element

normally closed (NC)

switching principle

Slow action, positive break opener

switching frequency

4,000 /hr

Electrical data – safety contacts

Voltage, utilization category AC-15

230VAC

Current, utilization category AC-15

4 A

Voltage, utilization category DC-13

24Vdc

Current, utilization category DC-13

4 A