• Large display with 8.6-mm character height.
• Includes new models with backlight for improved visibility in dimly lit places. (Requires 24-VDC power supply.)
• Black and light-gray cases now available.
• PNP/NPN universal DC voltage input types now available.
• Battery is replaceable for Totalizer reuse and conservation of the environment.
• Key-protect switch to prevent faulty reset key operation.
• Dual operation mode.
• Front face compatible with NEMA4/IP66.
• Short body, all models have a depth of 48.5 mm.
• Finger protection terminal block conforms to VDE0106, Part100.
• Conforms to UL, CSA, and CE marking.
Conforms to EN61010-1 (pollution degree 2/overvoltage category III.)
• Conforms to EMC standards and EN61326, thus allowing use in residential, commercial and light- and heavy-industry environments.
• Six-language instruction manual provided.
• PCB-mounting models available. (Requires 3-V power supply.)
Item | H7EC-NV-[] H7EC-NV-[]H |
H7EC-NFV-[] | H7EC-N-[] |
---|---|---|---|
Operating mode | Up type | ||
Mounting method | Flush mounting | ||
External connections | Screw terminals, optional Wire-wrap Terminals *1 | ||
Reset | External/Manual reset | ||
Number of digits | 8 | ||
Count input | PNP/NPN universal DC voltage input | AC/DC multi-voltage input | No-voltage input |
Display | 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) *2 | ||
Max. counting speed | 30 Hz/1 kHz | 20 Hz | 30 Hz/1 kHz |
Case color | Light gray or black (-B models) | ||
Attachment | Waterproof packing, Y92F-34 Flush Mounting Bracket | ||
Approved standard | UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III) Conforms to VDE0106/P100 |
*1. Separately ordered Wire-wrap Terminals (Y92S-37) are required.
*2. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
Item | H7EC-NV-[] H7EC-NV-[]H |
H7EC-NFV-[] | H7EC-N-[] |
---|---|---|---|
Supply voltage | Backlight model: 24 VDC (0.3 W max.) (only for backlight) No-backlight model: Not required (powered by built-in battery) |
Not required (powered by built-in battery) | |
Count input | High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) |
High (logic) level: 24 to 240 VAC/VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/VDC, 50/60 Hz |
No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. |
Reset input | No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. |
||
Max. counting speed * | 30 Hz or 1 KHz (Switchable with switch) |
20 Hz | 30 Hz or 1 KHz (Switchable with switch) |
Minimum signal width | 20 Hz: 25 ms 30 Hz: 16.7 ms 1 KHz: 0.5 ms |
||
Reset system | External reset and manual reset: Minimum signal width of 20 ms | ||
Terminal screw tightening torque | 0.98 Nm max. | ||
Ambient temperature | Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) |
||
Ambient humidity | Operating 25% to 85% |
Note: ON/OFF ratio 1:1
Item | H7EC-NV-[] H7EC-NV-[]H |
H7EC-NFV-[] | H7EC-N-[] |
---|---|---|---|
Insulation resistance | 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply terminal and count input terminals/reset terminals for backlight models | 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts and between count input terminals and reset terminals | 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply terminal and count input terminals/reset terminals for backlight models | 3,700 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between count input terminals and reset terminals | 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts |
Impulse withstand voltage | 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts | 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts 3 kV between input terminals and reset terminals | 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | ||
±600 V (Between count input terminals/Between reset terminals) ±480 V (Between the backlight power supply terminals for backlight models) |
±1.5 kV (Between count input terminals) ±500 V (Between reset terminals) |
±500 V (Between count input terminals/Between reset terminals) | |
Static immunity | ±8 kV (malfunction) | ||
Vibration resistance | Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions |
||
Shock resistance | Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions |
||
EMC | (EMI) EN61326-1 (See note 1.) Emission Enclosure: EN55011 Group 1 class B (EMS) EN61326-1 (See note 1.) Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3) 2 kV I/O signal line (level 4) |
||
Degree of protection | Front panel: IP66, NEMA4 Terminal block: IP20 |
||
Weight (see note 2.) | No-backlight model: Approx. 60 g Backlight model: Approx. 65 g |
Approx. 60 g | Approx. 60 g |
Note: 1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2. Weight includes waterproof packing and flush mounting bracket.
Item | Value | Note |
---|---|---|
Battery life | 7 years min. with continuous input at 25°C (lithium battery) |
The battery life is calculated according to the conditions in the left column and therefore is not a guaranteed value. Use these value as reference for maintenance or replacement. |
Item | H7ET-NV-[] H7ET-NV-[]H |
H7ET-NFV-[] | H7ET-N-[] | H7ET-NV1-[] H7ET-NV1-[]H |
H7ET-NFV1-[] | H7ET-N1-[] |
---|---|---|---|---|---|---|
Operating mode | Accumulating | |||||
Mounting method | Flush mounting | |||||
External connections |
Screw terminals | |||||
Reset | External/Manual reset | |||||
Display | 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) *1 | |||||
Number of digits | 7 | |||||
Time range | 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h (switchable with switch) |
0s to 999h59min59s ←→ 0.0min to 9999h59.9min (switchable with switch) |
||||
Timer input | PNP/NPN universal DC voltage input |
AC/DC multi- voltage input |
No-voltage input *2 |
PNP/NPN universal DC voltage input |
AC/DC multi- voltage input |
No-voltage input |
Case color | Light gray or black (-B models) | |||||
Attachment | Waterproof packing, Y92F-34 Flush Mounting Bracket, time unit labels *3 | |||||
Approved standard | UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III) Conforms to VDE0106/P100 |
*1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
*2. The frequency range for an AC voltage is 50 to 60 Hz.
*3. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.
*4. Zero suppression: Zeros are not displayed to increase readability. For example, “000008.2” is displayed as “8.2” if
zero suppression is set. If the range is set to 3999d23.9h, the value is “008.2”.
Item | H7ET-NV[]-[] H7ET-NV[]-[]H |
H7ET-NFV[]-[] | H7ET-N[]-[] |
---|---|---|---|
Supply voltage | Backlight model: 24 VDC (0.3 W max.) (for backlight) No-backlight model: Not required (powered by built-in battery) |
Not required (powered by built-in battery) | |
Timer input | High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) |
High (logic) level: 24 to 240 VAC/VDC, 50/60 Hz Low (logic) level: 0 to 2.4 VAC/VDC, 50/60 Hz |
No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. |
Reset input | No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. |
||
Minimum pulse width | 1 s | ||
Reset system | External reset and manual reset: Minimum signal width of 20 ms | ||
Terminal screw tightening torque | 0.98 Nm max. | ||
Ambient temperature | Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) |
||
Ambient humidity | Operating: 25% to 85% |
Item | H7ET-NV[]-[] H7ET-NV[]-H[] |
H7ET-NFV[]-[] | H7ET-N[]-[] |
---|---|---|---|
Time accuracy | ±100 ppm (25°C) | ||
Insulation resistance | 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and timer input terminals/reset terminals for backlight models | 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts and between timer input terminals and reset terminals | 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply and timer input terminals/reset terminals for backlight models | 3,700 VAC, 50/60 Hz for 1 min between timer input terminals and exposed noncurrent-carrying metal parts 2,200 VAC, 50/60 Hz for 1 min between reset terminals and exposed non-current-carrying metal parts and between timer input terminals and reset terminals |
1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts |
Impulse withstand | 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts | 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts 3 kV between timer input terminals and reset terminals |
4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | ||
±600 V (Between timer input terminals/Between reset terminals) ±480 V (Between the backlight power supply terminals for backlight models) |
±1.5 kV (Between timer input terminals) ±500 V (Between reset terminals) |
±500 V (Between timer input terminals/Between reset terminals) | |
Static immunity | ±8 kV (malfunction) | ||
Vibration resistance | Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions |
||
Shock resistance | Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions |
||
EMC | (EMI) EN61326-1 (See note 1.) Emission Enclosure: EN55011 Group 1 class B (EMS) EN61326-1 (See note 1.) Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2), 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3), 2 kV I/O signal line (level 4) |
||
Degree of protection | Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 |
||
Weight (see note 2.) | No-backlight model: Approx. 60 g Backlight model: Approx. 65 g |
Approx. 60 g | Approx. 60 g |
Note: 1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2. Weight includes waterproof packing and flush mounting bracket.
Item | Value | Note |
---|---|---|
Battery life | 10 years min. with continuous input at 25°C (lithium battery) |
The battery life is calculated according to the conditions in the left column and therefore is not a guaranteed value. Use these value as reference for maintenance or replacement. |
Item | H7ER-NV-[] H7ER-NV-[]H |
H7ER-N-[] | H7ER-NV1-[] H7ER-NV1-[]H |
---|---|---|---|
Operating mode | Up type | ||
Mounting method | Flush mounting | ||
External connections | Screw terminals, Wire-wrap Terminals *3 | ||
Display | 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) *4 | ||
Number of digits | 4 | 5 | |
Count input | PNP/NPN universal DC voltage input |
No-voltage input | PNP/NPN universal DC voltage input |
Max. counting speed | 1 kHz | 10 kHz | |
Max. revolutions displayed *5 *6 |
1,000 s-1 (When encoder resolution of 1 pulse/rev is used.) 1,000 min-1 (When encoder resolution of 60 pulse/rev is used.) |
1,000.0 s-1 (When encoder resolution of 10 pulse/ rev is used.) 1,000.0 min-1 (When encoder resolution of 600 pulse/rev is used.) ←→ 10,000 min-1 (When encoder resolution of 60 pulse/rev is used.) (Switchable with switch) |
|
Attachment | Waterproof packing, Y92F-34 Flush Mounting Bracket, revolution unit labels *5 | ||
Approved standard | UL863, CSA C22.2 No.14, Lloyds Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III) Conforms to VDE0106/P100 |
*1. Reset is not available.
*2. When there is no input, the display will be 0.0 or 0.
*3. Separately ordered Wire-wrap Terminals (Y92S-37) are required.
*4. Only PNP/NPN Universal DC voltage input models have a backlight.
*5. “rpm”, “rps”, “s-1” and “min-1” labels are included.
*6. “s-1” in “1,000 s-1” means the same thing as RPS. “min-1” means the same thing as RPM.
Item | H7ER-NV[]-[] H7ER-NV[]-[]H |
H7ER-N-[] |
---|---|---|
Supply voltage | Backlight model: 24 VDC (0.3 W max.) (for backlight lit) No-backlight model: Not required (powered by built-in battery) |
Not required (powered by built-in battery) |
Count input | High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kΩ) |
No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. |
Max. counting speed | 4-digit models: 1 kHz 5-digit models: 10 kHz |
1 kHz |
Minimum signal width | 10 kHz: 0.05 ms 1 kHz: 0.5 ms * |
|
Terminal screw tightening torque | 0.98 Nm max. | |
Ambient temperature | Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) |
|
Ambient humidity | Operating: 25% to 85% |
* 5-digit models :1 kHz/10 kHz switchable.
Item | H7ER-NV[]-[] H7ER-NV[]-[]H |
H7ER-N-[] |
---|---|---|
Insulation resistance | 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and count input terminals/reset terminals for backlight models |
100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply and count input terminals/reset terminals for backlight models |
1,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts |
Impulse withstand voltage | 4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts | |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | |
±600 V (Between count input terminals) ±480 V (Between the backlight power supply terminals for backlight models) |
±500 V (Between count input terminals) | |
Static immunity | ±8 kV (malfunction) | |
Vibration resistance | Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions |
|
Shock resistance | Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions |
|
EMC | (EMI) EN61326-1 (See note 1.) Emission Enclosure: EN55011 Group 1 class B (EMS) EN61326-1 (See note 1.) Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2), 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power line (level 3), 2 kV I/O signal line (level 4) |
|
Degree of protection | Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 |
|
Weight (see note 2.) | No-backlight model: Approx. 60 g Backlight model: Approx. 65 g |
Note: 1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2. Weight includes waterproof packing and flush mounting bracket.
Item | Value | Note |
---|---|---|
Battery life | 7 years min. with continuous input at 25°C (lithium battery) |
The battery life is calculated according to the conditions in the left column and therefore is not a guaranteed value. Use these value as reference for maintenance or replacement. |
Item | Total Counter | Time Counter | |
---|---|---|---|
H7EC-NP | H7EC-NLP | H7ET-NP | |
Operating mode | Up type | ||
Mounting method | Direct mounting on PC Board or mounting on 28-pin socket | ||
Reset | External reset, Power-OFF reset | ||
Number of digits | 8 | 7 | |
Time range | — | 0.0h to 999999.9h | |
Max. counting speed | 1 kHz | 30 Hz | — |
Count/Timer input | No-voltage input | ||
Display | 7-segment LCD (character height: 8.6 mm) | ||
Case color | Transparent | ||
Approved standard | UL863, CSA C22.2 No.14 |
Item | H7EC-NP H7EC-NLP |
H7ET-NP |
---|---|---|
Supply voltage | 3 VDC (2.7 to 3.3 VDC) | |
Count/Timer input | No voltage input Maximum short-circuit impedance: 10 kΩ max. Short-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kΩ min. |
|
Reset input | ||
Max. counting speed * | 1 kHz: Minimum signal width of 0.5 ms 30 Hz: Minimum signal width of 16.7 ms |
— |
Minimum signal input width | — | 1 s |
Reset system | External reset: Minimum signal width of 20 ms Power-OFF reset: Minimum power OFF time of 500 ms |
|
Ambient temperature | Operating: -10°C to 55°C (with no condensation or icing) Storage: -25°C to 65°C (with no condensation or icing) |
|
Ambient humidity | Operating: 25% to 85% |
* ON/OFF ratio 1:1
Item | H7EC-NP H7EC-NLP |
H7ET-NP |
---|---|---|
Time accuracy | — | ±100 ppm (25°C) |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±500 V (Between count or timer input terminals/Between reset terminals) |
|
Static immunity | ±8 kV (malfunction) | |
Vibration resistance | Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions |
|
Shock resistance | Malfunction: 200 m/s2 3 times each in 6 directions Destruction: 300 m/s2 3 times each in 6 directions |
|
EMC | (EMI) EN61326-1 (See note 1.) Emission Enclosure: EN55011 Group 1 class B (EMS) EN61326-1 (See note 1.) Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2), 8-kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance (see note): EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst (see note 2.): EN61000-4-4: 2-kV I/O signal line (level 4) |
|
Weight | Approx. 20 g |