• Capable of switching 1-A load at 240 VAC or 100 VDC.
• Maximum leakage current of 10 μA for OFF output.
• Withstand voltage 2,500 VAC between inputs and outputs.
• Built-in input resistance and overvoltage absorption circuit.
• Capable of AC full-wave rectification and half-wave rectification load operation.
Item | Input | Output | |||||||
---|---|---|---|---|---|---|---|---|---|
Rated voltage |
Operating voltage |
Impedance | Voltage level | Rated load voltage |
Load voltage range |
Load current * |
Surge with- stand current |
||
Model | Must- operate voltage |
Must- release voltage |
|||||||
G3RZ- 201SLN |
5 VDC | 4 to 6 VDC | 400 Ω ±20% | 4 VDC max. | 1 VDC min. |
5 to 240 VAC 5 to 100 VDC |
3 to 264 VAC 3 to 125 VDC |
100 μA to 1.0 A |
10 A (10 ms) |
12 VDC | 9.6 to 14.4 VDC |
1.1 kΩ ±20% | 9.6 VDC max. | ||||||
24 VDC | 19.2 to 28.8 VDC |
2.2 kΩ ±20% | 19.2 VDC max. |
Operation time | 6 ms max. |
---|---|
Release time | 10 ms max. |
Output ON resistance | 2.4 Ω max. |
OFF leakage current | 10 μA max. (at 125 VDC) 100 μA max. (at 200 VAC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | 2,500 VAC at 50/60 Hz for 1 min. between inputs and outputs |
Vibration resistance | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
Shock resistance | 1,000 m/s2 |
Storage temperature | -30 to 100°C (with no icing or condensation) |
Ambient operating temperature | -30 to +85°C (with no icing or condensation) |
Ambient operating humidity | 45% to 85% |
Weight | Approx. 20 g |
Model | Rated carry current |
Dielectric strength | nsulation resistance * |
Remarks |
---|---|---|---|---|
P2RF-05-PU | 10 A | Between contact terminals of same polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil and contact terminals: 4,000 VAC for 1 min | ||||
P2RFZ-05(-E) | 10 A | Between contact terminals of same polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil and contact terminals: 4,000 VAC for 1 min | ||||
P2RF-05 | 10 A | Between contact terminals of same polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil and contact terminals: 4,000 VAC for 1 min | ||||
P2R-05P | 10 A | Between contact terminals of same polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil and contact terminals: 4,000 VAC for 1 min | ||||
P2R-057P | 10 A | Between contact terminals of same polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between coil and contact terminals: 5,000 VAC for 1 min | ||||
P2R-05A | 10 A | Between contact terminals of same polarity: 1,000 VAC for 1 min |
1,000 MΩ min. | |
Between ground terminals: 1,500 VAC for 1 min | ||||
Between coil and contact terminals: 4,000 VAC for 1 min |