• Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can switch 5 amps of power.
• Sealed plastic construction used for relays.
• Easy wiring with separated input/output terminals.
• Special P6B Mounting Socket used to facilitate maintenance (except for high-reliability models).
• UL and CSA certification for standard models (except for high-reliability models). VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
• DIN Track mounting, and screw mounting models are available.
• SSR-equipped G3S4 models are also available.
Rated voltage | 5 VDC | 12 VDC | 24 VDC |
---|---|---|---|
Rated current | 35.5 mA (43.4) | 19.1 mA | 10.7 mA (10.3) |
Coil resistance | 125 Ω | 720 Ω | 2,880 Ω |
Must operate voltage | 80% max. of rated voltage | ||
Must release voltage | 10% min. of rated voltage | ||
Max. voltage | 130% of rated voltage | ||
Power consumption | Approx. 200 mW |
Classification | G6B-4BND (standard), G6B-47BND (long-life) | G6B-48BND (high-reliability) | ||
---|---|---|---|---|
Load | Resistive load (cosφ = 1) |
Inductive load (cosφ = 0.4, L/R = 7 ms) |
Resistive load (cosφ = 1) |
Inductive load (cosφ = 0.4, L/R = 7 ms) |
Rated load | 5 A at 250 VAC, 5 A at 30 VDC |
2 A at 250 VAC, 2 A at 30 VDC |
2 A at 250 VAC, 2 A at 30 VDC |
0.5 A at 250 VAC, 0.5 A at 30 VDC |
Rated carry current | 5 A | 2 A | ||
Max. switching voltage | 380 VAC, 125 VDC | |||
Max. switching current | 5 A | 2 A | 2 A | 0.5 A |
Max. switching power | 1,250 VA, 150 W | 500 VA, 60 W | 500 VA, 60 W | 125 VA, 15 W |
Error rate (reference value) (see note) |
10 mA at 5 VDC | 1 mA at 1 VDC |
Contact resistance (see note 2) |
100 mΩ max. |
---|---|
Operate time | 10 ms max. (approx. 3 ms) |
Release time | 15 ms max. (approx. 4 ms) |
Insulation resistance | 1,000 MΩ min. (at 500 VDC) |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between coil and contacts 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 250 VAC, 50/60 Hz for 1 min between coils of different polarity |
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
Shock resistance | Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 100 m/s2 (approx. 10G) |
Endurance | Mechanical: 50,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr, rated load) 500,000 operations min. for long-life at 2 A 100,000 operations min for long-life at 5 A |
Ambient temperature | Operating: -25°C to 55°C (with no icing or condensation) Storage: -25°C to 55°C (with no icing or condensation) |
Ambient humidity | Operating: 35% to 85% |
Weight | Approx. 75 g |