The WL Series provides a complete range of Limit Switches with a long history of meeting user needs. Select environment-resistant specifications, actuators for essentially any workpiece, operating sensitivity matched to the workpiece, operation indicators to aid operation and maintenance, and various wiring specifications.
Agency | Standard | File No. | Approved models |
---|---|---|---|
UL | UL508 | E76675 | Contact your OMRON representative for information on approved models. |
CSA | CSA C22.2 No.14 | LR45746 | |
TÜV Rheinland | EN60947-5-1 | J50022353, J9950023, J9950959 | |
CCC (CQC) | GB/T14048.5 | Contact your OMRON representative for details. |
Item | Rated voltage (V) |
Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | ||||||
NC | NO | NC | NO | NC | NO | NC | NO | ||
Basic models, overtravel models |
125 VAC 250 VAC 500 VAC |
10 10 10 |
3 2 1.5 |
1.5 1 0.8 |
10 10 3 |
5 3 1.5 |
2.5 1.5 0.8 |
||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
3 3 3 0.2 0.1 |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 20 A max. |
Minimum applicable load | 5 VDC 160 mA |
---|
Rated voltage (V) | Rated current (A) – Resistive load |
---|---|
AC 125 | 0.1 |
DC 30 |
Operation in the following ranges will produce optimum performance.
Recommended load range | 5 to 30 VDC 0.5 to 100 mA |
---|
Recommended load range | 5 VDC 1 mA |
---|
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC 480 VAC 600 VAC |
10 A | 60 30 15 12 |
6 3 1.5 1.2 |
7,200 | 720 |
0.1 A 125 VAC, 0.1 A 30 VDC
Model | Application category and ratings | Thermal current (Ithe) | Indicator |
---|---|---|---|
WL[] | AC-15: 2 A/250 V DC-12: 2 A/48 V |
10 A | — |
WL01[] | AC-14: 0.1 A/125V DC-12: 0.1 A/48 V |
0.5 A | — |
WL[]-LE | AC-15: 2 A/250 V | 10 A | Neon lamp |
WL01[]-LE | AC-14: 0.1 A/125 V | 0.5 A | Neon lamp |
WL[]-LD | AC-15: 2 A/115 V DC-12: 2 A/48 V |
10 A | LED |
WL01[]-LD | AC-14: 0.1 A/115 V DC-12: 0.1 A/48 V |
0.5 A | LED |
Note: As an example, AC-15: 2 A/250 V means the following:
Application category | AC-15 |
---|---|
Rated operating current (Ie) | 2A |
Rated operating voltage (Ue) | 250V |
Item | Max. rated voltage (V) | Leakage current (mA) | |
---|---|---|---|
WL-LE | Neon lamp | 125 AC | Approx. 0.6 |
250 AC | Approx. 1.9 | ||
WL-LD | LED | 115 AC/DC | Approx. 0.5 |
10 to 24 AC/DC | Approx. 0.4 |
Degree of protection | IP67 | |
---|---|---|
Durability *1 |
Mechanical | 15,000,000 operations min. *2 |
Electrical | 750,000 operations min. *3 | |
Operating speed | 1 mm/s to 1 m/s (in case of WLCA2) | |
Operating frequency |
Mechanical | 120 operations/minute min. |
Electrical | 30 operations/minute min. | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 25 mΩ max. (initial value for the built-in switch when tested alone) *6 | |
Dielectric strength |
Between terminals of the same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between current-carrying metal part and ground |
2,200 VAC, 50/60 Hz for 1 min/Uimp 2.5 kV | |
Between each terminal and non- current-carrying metal part |
2,200 VAC, 50/60 Hz for 1 min/Uimp 2.5 kV | |
Rated insulation voltage (Ui) | 250 V (EN60947-5-1) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A, fuse type gG or gI (IEC60269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 10 A, 0.5 A (EN60947-5-1) | |
Protection against electric shock | Class I | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *4 |
Shock resistance |
Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. *4 | |
Ambient operating temperature | -10°C to +80°C (with no icing) *5 | |
Ambient operating humidity | 35% to 95% RH | |
Weight | Approx. 275 g (in case of WLCA2) |
Item | Rated voltage (V) |
Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | ||||||
NC | NO | NC | NO | NC | NO | NC | NO | ||
WL[]-LES | 125 VAC 250 VAC |
10 10 |
3 2 |
1.5 1 |
10 10 |
5 5 |
2.5 1.5 |
||
WL[]-LDS | 115 VAC | 10 | 3 | 1.5 | 10 | 5 | 2.5 | ||
12 VDC 24 VDC 48 VDC |
10 6 3 |
6 4 2 |
3 3 1.5 |
10 6 3 |
6 4 2 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 20 A max. | |
Operating temperature | -10°C to +80°C (with no icing) | |
Operating humidity | 35% to 95%RH max. |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC |
10 A | 60 30 |
6 3 |
7,200 | 720 |
Rated voltage | Carry current |
---|---|
115 VAC | 10 A |
115 VDC | 0.8 A |
Model | Application category and ratings |
---|---|
WL[] | AC-15: 2 A/250 V DC-12: 2 A/48 V |
WL01[] | AC-14: 0.1 A/125V DC-12: 0.1 A/48 V |
WL[]-LE | AC-15: 2 A/250 V |
WL01[]-LE | AC-14: 0.1 A/125 V |
WL[]-LD | AC-15: 2 A/115 V DC-12: 2 A/48 V |
WL01[]-LD | AC-14: 0.1 A/115 V DC-12: 0.1 A/48 V |
Note: As an example, AC-15: 2 A/250 V means the following:
Application category | AC-15 |
---|---|
Rated operating current (Ie) | 2 A |
Rated operating voltage (Ue) | 250 V |
Degree of protection | IP67 | |
---|---|---|
Durability *1 |
Mechanical | 15,000,000 operations min. *2 |
Electrical | 750,000 operations min. *3 | |
Operating speed | 1 mm/s to 1 m/s (in case of WLCA2) | |
Operating frequency |
Mechanical | 120 operations/minute min. |
Electrical | 30 operations/minute min. | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 25 mΩ max. (initial value for the built-in switch when tested alone) | |
Dielectric strength |
Between terminals of the same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between current-carrying metal part and ground |
2,200 VAC, 50/60 Hz for 1 min/Uimp 2.5 kV | |
Between each terminal and non- current-carrying metal part |
2,200 VAC, 50/60 Hz for 1 min/Uimp 2.5 kV | |
Rated insulation voltage (Ui) | 250 V (EN60947-5-1) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Short-circuit protective device (SCPD) | 10 A, fuse type gG or gI (IEC60269) | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 10 A, 0.5 A (EN60947-5-1) | |
Protection against electric shock | Class I | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance |
Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. | |
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 275 g (in case of WLCA2) |
Item | Rated voltage (V) |
Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | ||||||
NC | NO | NC | NO | NC | NO | NC | NO | ||
Basic models, overtravel models |
115 AC | 10 | 3 | 1.5 | 10 | 5 | 2.5 | ||
12 DC 24 DC 48 DC 115 DC |
10 6 3 0.8 |
6 4 2 0.2 |
3 3 1.5 0.2 |
10 6 3 0.8 |
6 4 2 0.2 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 20 A max. |
Model | Rated voltage (V) |
Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | ||||||
NC | NO | NC | NO | NC | NO | NC | NO | ||
DC | 12 DC | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
24 DC | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
48 DC | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
115 DC | 0.8 | 0.8 | 0.2 | 0.2 | 0.8 | 0.8 | 0.2 | 0.2 | |
AC | 115 AC | 3 | 3 | 3 | 1.5 | 3 | 3 | 3 | 2.5 |
Degree of protection | IP67 | |
---|---|---|
Durability * |
Mechanical | 30,000,000 operations min. |
Electrical | 30,000,000 operations min. (10 mA at 24 VDC, resistive load) 750,000 operations min. (10 A at 115 VAC, resistive load) |
|
Operating speed | 1 mm/s to 1 m/s (in case of WLCA2) | |
Operating frequency |
Mechanical | 120 operations/minute |
Electrical | 30 operations/minute | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 25 mΩ max. (initial value for the built-in switch when tested alone) | |
Dielectric strength (50/60 Hz for 1 min) |
Between terminals of the same polarity |
1,000 VAC (except connector models) |
Between current-carrying metal part and ground |
2,200 VAC (1,500 V) | |
Between each terminal and non-current- carrying metal part |
2,200 VAC (1,500 V) | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance |
Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. | |
Ambient operating temperature | -10°C to +80°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 275 g (in case of WLCA2) |