Measuring range |
PE: pulse-echo mode 0.65 … 600 mm (steel) |
|
EE: echo-echo mode 2.50 … 60 mm |
Accuracy |
± 0.04 mm H [mm] (<10 mm); ± 0.4% H [mm] (> 10 mm) |
|
H refers to the material thickness of the workpiece |
Resolution |
0.1 mm / 0.01 mm / 0.001 mm (adjustable) |
|
|
Measurable materials |
Metals |
|
Plastics |
|
Ceramics |
|
Epoxy resin |
|
Glass |
|
And all homogeneous materials |
|
|
Working modes |
Pulse echo mode (fault and blower detection) |
|
Echo-Echo mode (hiding layer thicknesses, eg paints) |
|
|
Calibration |
Sound velocity calibration |
|
Zeroing |
|
Two-point calibration |
|
|
View mode |
Normal mode, Scan mode, Difference mode |
Units |
mm / inch |
Data transfer |
Print via Bluetooth / USB 2.0 |
Storage |
Non-volatile memory with 100 data groups with 100 data sets each |
Operating time |
Continuous operation 100 h |
|
Automatic stand-by mode (adjustable) |
|
Automatic switch-off mode (adjustable) |
|
|
Power supply |
4 x AA battery 1.5V |
Display |
320 x 240 pixels TFT LCD color display with brightness adjustment |
Operating conditions |
0 … 50°C / 32 … 122°F, ≤ 80% RH not condensing |
Storage conditions |
-20 … 70°C / -4 … 158°F, ≤ 80% rh non-condensing |
Dimensions |
185 x 97 x 40 mm / 7.3 x 3.8 x 1.6 in |
Weight |
375 g / < 1 lb |
|
|
Specification of the available sensors for wall thickness gauge PCE-TG 300 |
|
|
NO2 |
|
Frequency |
2.5 MHz |
Diameter |
14 mm |
Measuring range |
3 … 40 mm (steel) |
|
3 … 300 mm (steel) |
Minimum diameter of pipes |
Not suitable for curved materials |
Description |
For damping / scattering materials (plastics, cast iron) |
|
|
NO5 |
|
Frequency |
5 MHz |
Diameter |
10 mm |
Measuring range |
1 … 600 mm (steel) |
Minimum diameter of pipes |
20 x 3 mm |
Description |
Normal measurement |
|
|
NO5 / 90° |
|
Frequency |
5 MHz |
Diameter |
10 |
Measuring range |
1 … 600 mm (steel) |
Minimum diameter of pipes |
20 x 3 mm |
Description |
Normal measurement |
|
|
NO7 |
|
Frequency |
7 MHz |
Diameter |
6 mm |
Measuring range |
0.65 … 200 mm (steel) |
Minimum diameter of pipes |
15 x 2 mm |
Description |
Or thin-walled or heavily curved pipes |
|
|
HT5 |
|
Frequency |
5 MHz |
Diameter |
12 mm |
Measuring range |
1 … 600 mm (steel) |
Minimum diameter of pipes |
30 mm |
Description |
For high temperatures (max 300°C / 572°F) |
|
|
P5EE |
|
Frequency |
5 MHz |
Diameter |
10 mm |
Measuring range |
PE: 2 … 600 mm, EE: 2.5 … 100 mm |
Minimum diameter of pipes |
20 x 3 mm |
Description |
Normal measurement and EE test |
|
|