• A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC with H3DS-XL[])
• Smart Dial/Selector-locking Mechanism: Prevents the dials and selectors on the Timer’s front panel from being inadvertently operated or being operated without authorization. The lock can only be unlocked and locked with an optional pen-type Lock Key.
• Screw-Less Clamp type available. (H3DS-[]LC)
• Sticker provided for easy timer identification and management.
• Terminal clamp left open when delivered (screw terminal type).
• Finger protection terminal block to meet VDE0106/P100.
• Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.
• Incorporates environment-friendly, cadmium-free contacts.
• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.
Item | H3DS-ML[] | H3DS-SL[] | H3DS-AL[] |
---|---|---|---|
Operating mode | A: ON-delay (Signal or Power) B: Flicker OFF start (Signal or Power) B2: Flicker ON start (Signal or Power) C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval (Signal or Power) G: Signal ON/OFF-delay J: One-shot (Signal or Power) |
A: ON-delay B2: Flicker ON start E: Interval J: One-shot |
A: ON-delay (fixed) |
Input type | Voltage input | — | |
Output type | Relay: SPDT | ||
External connections | Screw terminal, Screw-Less Clamp | ||
Terminal block | Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves. Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves. |
||
Terminal screw tightening torque |
0.98 Nm max. | ||
Mounting method | DIN track mounting * | ||
Attachment | Nameplate label | ||
Approved standards | UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100 Output category according to IEC60947-5-1 (AC-13; 250 V 5 A/AC-14; 250 V 1 A/AC-15; 250 V 1 A/DC-13; 30 V 0.1 A/DC-14; 30 V 0.05 A) |
* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.
Time scale display | Time range |
---|---|
0.1 s | 0.1 to 1.2 s |
1 s | 1 to 12 s |
0.1 m | 0.1 to 1.2 min |
1 m | 1 to 12 min |
0.1 h | 0.1 to 1.2 h |
1 h | 1 to 12 h |
10 h | 10 to 120 h |
Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.
Rated supply voltage *1, *2 | 24 to 230 VAC (50/60 Hz)/24 to 48 VDC |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power reset | Minimum power-off time: 0.1 s |
Reset voltage | 2.4 VAC/DC max. |
Power consumption *3 | AC: 32 VA max./3.0 W max. (typical: 30 VA/2.7 W) at 230 VAC DC: 0.7 W max. (typical: 0.6 W) at 24 VDC 1.4 W max. (typical: 1.3 W) at 48 VDC |
Voltage input | Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF Load connectable in parallel with inputs (terminals B1 and A1). H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC L-level: 0 to 2.4 VAC/DC |
Control output | Contact output: 5 A at 250 VAC with resistive load (cosφ = 1) 1 A at 250 VAC with inductive load (cosφ = 0.3) 5 A at 30 VDC with resistive load (cosφ = 1) 0.15 A max. at 125 VDC with resistive load, 0.1 A max. at 125 VDC with L/R of 7 ms. The minimum applicable load is 10 mA at 5 VDC (P reference value). Contact materials: Ag-alloy |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
Accuracy of operating time |
±1% max. of FS (±1% ±10 ms max. at 1.2-s range) |
---|---|
Setting error | ±10% ±50 ms max. of FS |
Signal input time | 50 ms min. |
Influence of voltage | ±0.7% max. of FS (±0.7% ±10 ms max. at 1.2-s range) |
Influence of temperature |
±5% max. of FS (±5%±10 ms max. at 1.2-s range) |
Insulation resistance | 100 MΩ min. at 500 VDC |
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min. Between control output terminals and operating circuit: 2,000 VAC for 1 min. Between contacts not located next to each other: 1,000 VAC for 1 min. |
Vibration resistance | Malfunction: 0.5-mm single amplitude at 10 to 55 Hz Destruction: 0.75-mm single amplitude at 10 to 55 Hz |
Shock resistance | Malfunction: 100 m/s2 3 times each in 6 directions Destruction: 1,000 m/s2 3 times each in 6 directions |
Impulse withstand voltage |
5 kV (between power terminals) 5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts) |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV |
Static immunity | Malfunction: 4 kV Destruction: 8 kV |
Life expectancy | Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) * |
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B Harmonic Current: EN61000-3-2 Voltage Fluctuation and Flickering: EN61000-3-3 (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption: IEC61000-4-11 |
Case color | Light gray (5Y7/1) |
Degree of protection | IP30 (Terminal block: IP20) |
Weight | Approx. 70 g |
Item | H3DS-F |
---|---|
Operating mode | Flicker-OFF/Flicker-ON start |
Output type | Relay: SPDT |
External connections | Screw terminal, Screw-Less Clamp |
Terminal block | Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves. Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves. |
Terminal screw tightening torque |
0.98 Nm max. |
Mounting method | DIN track mounting * |
Attachment | Nameplate label |
Approved standards | UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P 100 Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/DC-13; 30 V 0.1 A) |
* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.
Time scale display | Time range |
---|---|
0.1 s | 0.1 to 1.2 s |
1 s | 1 to 12 s |
0.1 m | 0.1 to 1.2 min |
1 m | 1 to 12 min |
0.1 h | 0.1 to 1.2 h |
1 h | 1 to 12 h |
Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.
Rated supply voltage * | 24 to 230 VAC (50/60 Hz)/24 to 48 VDC |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power reset | Minimum power-off time: 0.1 s |
Reset voltage | 2.4 VAC/DC max. |
Power consumption | AC: 33 VA max./2.2 W max. (typical: 31 VA/2.0 W) at 230 VAC DC: 0.7 W max. (typical: 0.6 W) at 24 VDC 1.4 W max. (typical: 1.2 W) at 48 VDC |
Voltage input | Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF Load connectable in parallel with inputs (terminals B1 and A1). H-level: 20.4 to 253 VAC/20.4 to 52.8 VDC L-level: 0 to 2.4 VAC/DC |
Control output | Contact output: 5 A at 250 VAC with resistive load (cosφ = 1) 1 A at 250 VAC with inductive load (cosφ = 0.3) 5 A at 30 VDC with resistive load (cosφ = 1) |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
* DC ripple rate: 20% max.
Accuracy of operating time |
±1% max. of FS (±1% ±10 ms max. at 1.2-s range) |
---|---|
Setting error | ±10% ± 50 ms max. of FS |
Influence of voltage | ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range) |
Influence of temperature |
±5% max. of FS (±5% ± 10 ms max. at 1.2-s range) |
Insulation resistance | 100 MΩ min. at 500 VDC |
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1 min. Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min. Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min. |
Impulse withstand voltage |
3 kV (between power supply terminals) 4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts) |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV |
Static immunity | Malfunction: 4 kV Destruction: 8 kV |
Vibration resistance | Malfunction: 0.5-mm single amplitude at 10 to 55 Hz Destruction: 0.75-mm single amplitude at 10 to 55 Hz |
Shock resistance | Malfunction: 200 m/s2, 3 times each in 6 directions Destruction: 300 m/s2, 3 times each in 6 directions |
Life expectancy | Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) * |
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B Harmonic Current: EN61000-3-2 Voltage Fluctuation and Flickering: EN61000-3-3 (EMS) EN61812-1 Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3), 1 kV control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kV common mode (level 3), 1 kV differential mode (level 3) |
Case color | Light gray (5Y7/1) |
Degree of protection | IP30 (IP20 for terminal block) |
Weight | Approx. 70 g |
Item | H3DS-G |
---|---|
Operating mode | Star-delta operation |
Operating/Reset method | Time-limit operation/Self-reset |
External connections | Screw terminal, Screw-Less Clamp |
Terminal block | Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves. Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves. |
Terminal screw tightening torque |
0.98 Nm max. |
Output type | (Star operation circuit) Relay: SPST-NO (Delta operation circuit) Relay: SPST-NO |
Mounting method | DIN track mounting * |
Attachment | Nameplate label |
Approved standards | UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100 Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 1 A/ DC-13; 30 V 0.1 A) |
* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.
Time scale | Star operation time ranges | |
---|---|---|
x 1 | 1 to 12 s | |
x 10 | 10 to 120 s |
Star-delta transfer time | Programmable at 0.05 s, 0.1 s, 0.5 s, or 1 s |
---|
Rated supply voltage * | 24 to 230 VAC (50/60 Hz)/24 to 48 VDC |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power reset | Minimum power-off time: 0.5 s |
Reset voltage | 2.4 VAC/DC max. |
Power consumption | AC: 21 VA max./1.7 W max. (typical: 20 VA/1.6 W) at 230 VAC DC: 1.3 W max. (typical: 1.2 W) at 24 VDC 0.7 W max. (typical: 0.6 W) at 48 VDC |
Control output | Contact output: 5 A at 250 VAC with resistive load (cosφ = 1) 1 A at 250 VAC with inductive load (cosφ = 0.3) 5 A at 30 VDC with resistive load (cosφ = 1) |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
* DC ripple rate: 20% max.
Accuracy of operating time |
±1% max. of FS |
---|---|
Setting error | ±10% ± 50 ms max. of FS |
Total tolerance of transfer time |
± (25% FS + 5 ms) max. |
Influence of voltage | ±0.5% max. of FS |
Influence of temperature |
±5% max. of FS |
Insulation resistance | 100 MΩ min. at 500 VDC |
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1 min. Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min. Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min. |
Impulse withstand voltage |
3 kV (between power supply terminals) 4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts) |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV |
Static immunity | Malfunction: 4 kV Destruction: 8 kV |
Vibration resistance | Malfunction: 0.5-mm single amplitude at 10 to 55 Hz Destruction: 0.75-mm single amplitude at 10 to 55 Hz |
Shock resistance | Malfunction: 200 m/s2, 3 times each in 6 directions Destruction: 300 m/s2, 3 times each in 6 directions |
Life expectancy | Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) * |
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B Harmonic Current: EN61000-3-2 Voltage Fluctuation and Flickering: EN61000-3-3 (EMS) EN61812-1 Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3), 1 kV control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kV common mode (level 3), 1 kV differential mode (level 3) |
Case color | Light gray (5Y7/1) |
Degree of protection | IP30 (IP20 for terminal block) |
Weight | Approx. 70 g |
Item | H3DS-X |
---|---|
Operating mode | ON-delay |
Operating/Reset method | Time-limit operation/self-resetting |
Output type | SCR output |
External connections | Screw terminal, Screw-Less Clamp |
Terminal block | Screw terminal type: Clamps two 2.5-mm2 max. bar terminals without sleeves. Screw-Less Clamp type: Clamps two 1.5-mm2 max. bar terminals without sleeves. |
Terminal screw tightening torque |
0.98 Nm max. |
Mounting method | DIN track mounting * |
Attachment | Nameplate label |
Approved standards | UL508, CSA C22.2 No.14 Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100 |
* Can be mounted to 35-mm DIN Track with a plate thickness of 1 to 2.5 mm.
Time scale display | Time range |
---|---|
0.1 s | 0.1 to 1.2 s |
1 s | 1 to 12 s |
0.1 m | 0.1 to 1.2 min |
1 m | 1 to 12 min |
0.1 h | 0.1 to 1.2 h |
1 h | 1 to 12 h |
10 h | 10 to 120 h |
Note: When the time setting dial is set to “0” for any time scale, the output will operate instantaneously.
Rated supply voltage * | 24 to 230 VAC/VDC (50/60 Hz) |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power reset | Minimum power-off time: 0.1 s |
Reset voltage | 1.0 VAC/VDC max. |
Reset current | 5 mA max. |
Power consumption | 5 mA max. |
Control output | SCR output: 5 mA to 0.7 A |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
* The ripple in DC power supply must be 5% max.
Accuracy of operating time |
±1% max. of FS (±1% ±10 ms max. at 1.2-s range) |
---|---|
Setting error | ±10% ± 50 ms max. of FS |
Reset time | 0.1 s max. |
Influence of voltage | ±0.5% max. of FS (±0.5%±10 ms max. at 1.2-s range) |
Influence of temperature |
±5% max. of FS (±5%±10 ms max. at 1.2-s range) |
Insulation resistance | 100 MΩ min. at 500 VDC |
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min |
Impulse withstand voltage |
3 kV (between power supply terminals) 4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts) |
Noise immunity | Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV (between power supply terminals) |
Static immunity | Malfunction: 4 kV Destruction: 8 kV |
Vibration resistance | Malfunction: 0.5-mm single amplitude at 10 to 55 Hz Destruction: 0.75-mm single amplitude at 10 to 55 Hz |
Shock resistance | Malfunction: 200 m/s2, 3 times each in 6 directions Destruction: 300 m/s2, 3 times each in 6 directions |
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B Harmonic Current: EN61000-3-2 Voltage Fluctuation and Flickering: EN61000-3-3 (EMS) EN61812-1 Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3), 1 kV control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kV common mode (level 3), 1 kV differential mode (level 3) |
Case color | Light gray (5Y7/1) |
Degree of protection | IP30 (IP20 for terminal block) |
Weight | Approx. 70 g |