• Direct opening mechanism (NC contacts only) added to enable opening contacts when faults occur, such as fused contacts.
• Safety of lever settings ensured using a mechanism that engages a gear between the operating position indicator plate and the lever.
• Equipped with a mechanism that indicates the applicable operating zone, as well as push-button switching to control left and right motion.
• Head seal structure strengthened to improve seal properties (TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
•Wide standard operating temperature range:
–40 to 80°C (standard type).
• Certified standards: UL, CSA, EN (TÜV), and CCC.
• Machinery Directive
• Low Voltage Directive
• EN50041
• EN60204-1
• EN ISO 14119
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland | EN60947-5-1 (certified direct opening mechanism) GS-ET-15 |
Consult your OMRON representative for details. |
EN60947-5-1 (uncertified direct opening mechanism) | J50005477 * | |
UL | UL508 | E76675 |
CSA | C22.2 No. 14 | LR45746 |
CQC (CCC) | GB/T14048.5 | Contact your OMRON representative for details. |
* Adjustable roller lever, adjustable rod lever only.
Certification body | Standard | File No. |
---|---|---|
TÜV Rheinland | EN60947-5-1 (certified direct opening mechanism) GS-ET-15 |
Consult your OMRON representative for details. |
EN60947-5-1 (uncertified direct opening mechanism) | J50005477 * | |
UL | UL508 | E76675 |
CSA | C22.2 No. 14 | LR45746 |
CQC (CCC) | GB/T14048.5 | Contact your OMRON representative for details. |
* Adjustable roller lever, adjustable rod lever only.
Utilization category | AC-15 |
---|---|
Rated operating current (Ie) | 2 A |
Rated operating voltage (Ue) | 400 V |
Note: As protection against short-circuiting, use either a gI-type or gG-type 10 A fuse that conforms to IEC60269.
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC 480 VAC 600 VAC |
10 A | 60 30 15 12 |
6 3 1.5 1.2 |
7,200 | 720 |
Rated voltage (V) | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 400 |
10 10 10 |
3 2 1.5 |
1.5 1 0.8 |
10 10 3 |
5 3 1.5 |
2.5 1.5 0.8 |
||
8 VDC 14 30 125 250 |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
3 3 3 0.2 0.1 |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
Note: 1. The above values are continuous currents.
2. Inductive loads have a power factor of 0.4 or higher (AC) or a time constant of 7 ms or lower (DC).
3. Lamp loads have a inrush current of 10 times the normal current.
4. Motor loads have a inrush current of 6 times the normal current.
Inrush current | 30 A max. |
---|
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 30,000,000 operations min. (snap-action) 10,000,000 operations min. (slow-action) |
Electrical | 500,000 operations min. (10 A resistive load at 250 VAC) | |
Operating speed | 1 mm/s to 0.5 m/s | |
Operating frequency | Mechanical | 120 operations/minute |
Electrical | 30 operations/minute | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *3 | 180 mA resistive load at 5 VAC (N-level reference value) |
|
Rated insulation voltage (Ui) | 600 V (EN60947-5-1) | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class I (with ground terminal) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity |
2.5 kV (snap-action)/4 kV (slow-action) |
Between terminals of different polarity |
4 kV (slow-action) | |
Between each terminal and ground |
4 kV | |
Insulation resistance | 100 MΩ min. (at 500 VDC) between terminals of the same polarity and between each terminal and non-current-carrying part |
|
Contact gap | 2 × 2 mm min. (slow-action) 2 × 0.5 mm min. (snap-action) |
|
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional enclosed thermal current (Ithe) | 20 A (EN60947-5-1) | |
Ambient operating temperature | -40 to 80°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 250 g |