Order-Number: 06369836
The ideal probe for fast and accurate determination of the pressure dew point. In addition, it is suitable for high-precision measurements in the trace humidity range and also enables fine adjustment to any pressure dew point in the -40 to +25 °C tpd range at +25 °C (single-point adjustment).
Humidity – Capacitive | |
---|---|
Measuring range | 0 to +100 %RH |
Pressure dewpoint | |
---|---|
Measuring range | -40 to +50 °Ctpd |
Accuracy | ±0.8 °Ctpd (-4.9 to +50 °Ctpd)
±1 °Ctpd (-9.9 to -5 °Ctpd) ±2 °Ctpd (-19.9 to -10 °Ctpd) ±3 °Ctpd (-29.9 to -20 °Ctpd) ±4 °Ctpd (-40 to -30 °Ctpd) |
General technical data | |
---|---|
Length probe shaft | 300 mm |