Enviro-LOGO

G9H

• Reduces wiring work by 60% when combined with the PTF-08-PU Push-In Plus Socket (according to actual OMRON measurements).

• UL/CSA certified (-US models).

• Using a triac to open and close the circuit reduces chattering and arching, thereby increasing the electrical durability to 10 million operations.

• Relays contacts for power ON and 10-A switching with high-capacity are provided in a compact body without the need of radiators. Plus, there is almost no effect on heat generation or ambient temperature.

• Operation indicators to easily check operation.

• Built-in temperature fuse prevents internal burning due to triac or relay malfunctions.

• Socket-type Relays the same size as the 1-pole and 2-pole LY Relays.

Ratings

Input

Rated
voltage
Item Operating voltage Coil
resistance
Must operate
voltage
Must release
voltage
Power consumption
DC 5 V 4 to 6 VDC 104 Ω 4 VDC max. 0.5 VDC min. Approx. 240 mW
12 V 9.6 to 14.4 VDC 600 Ω 9.6 VDC max. 1.2 VDC min.
24 V 19.2 to 28. 8 VDC 2,400 Ω 19.2 VDC max. 2.4 VDC min.

 

Note: 1. The coil resistance is measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Performance characteristic data are measured at a coil temperature of 23°C.

Output

Item Applicable load
Model Rated load
voltage
Load voltage
range
Load current
(See note.)
Inrush current resistance
G9H-205S (-US) 100 to 240 VAC 75 to 264 VAC 50 mA to 5 A (at 55°C) 80 A (60 Hz, 1 cycle)
G9H-210S (-US) 50 mA to 10 A (at 55°C) 170 A (60 Hz, 1 cycle)

 

Note: The load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature
in Engineering Data.

Characteristics

Item G9H-205S (-US) G9H-210S (-US)
Operate time 10 ms max.
Release time 1/2 cycle max. + 10 ms
Output ON voltage drop 1.6 V max. (RMS) (at 5 A) 1.6 V max. (RMS) (at 10 A)
Leakage current 5 mA max. at 250 VAC
Inrush current resistance 80 A 170 A
Temperature rise 50°C max. (rated voltage applied using resistance method)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC 50/60 Hz 1 min
Vibration resistance Destruction 10 to 55 to 10 Hz, 1-mm single amplitude (2-mm double amplitude)
Malfunction 10 to 45 to 10 Hz, 1-mm single amplitude (2-mm double amplitude)
Shock resistance
(See note.)
Destruction 1,000 m/s2
Malfunction 100 m/s2
Life expectancy Mechanical 10 million operations min. (switching frequency: 18,000 operations/hour)
Electrical 10 million operations min. (resistive load and switching frequency: 18,000 operations/hour)
Storage temperature -25 to 70°C (with no icing or condensation)
Ambient operating temperature -25 to 60°C (with no icing or condensation)
Ambient operating humidity 35% to 85%
Weight Approx. 25 g

 

Model Rated
carry current
Dielectric strength Insulation
resistance *1
Remarks
PTF-08-PU 10 A Between contact terminals of different polarity: 2,000 VAC, 1 min 1,000 MΩ min.
Between contact terminals of same polarity: 2,000 VAC, 1 min
Between coil and contact terminals: 2,000 VAC, 1 min
PTFZ-08-E 12 A ([]70°C)
*2
Between contact terminals of different polarity: 2,500 VAC, 1 min 1,000 MΩ min.
Between contact terminals of same polarity: 2,500 VAC, 1 min
Between ground terminals: 2,500 VAC, 1 min
Between coil and contact terminals: 2,500 VAC, 1 min
PTF08A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT-08 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT08-0 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT08QN 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.