• SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input).
• Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
• All Output Relays provide a long endurance (1,000,000 operations at 5 A), while all Input Relays provide microswitching power (100 μA at 1 V).
• Approved by UL and CSA standards.
Rated voltage (V) | Rated current | Coil resistance |
Must operate voltage |
Must release voltage |
Max. voltage | Power consumption |
||
---|---|---|---|---|---|---|---|---|
50 Hz | 60 Hz | |||||||
AC | 100/110 | 8.2/9 mA | 7/7.7 mA | 8,700 Ω | 80% max. of rated value |
30% min. of rated value |
110% of rated value |
0.7 VA |
200/220 | 4.1/4.5 mA | 3.5/3.85 mA | 33,300 Ω | |||||
DC | 12 | 42 mA | 290 Ω | 80% max. of rated value |
10% min. of rated value |
110% of rated value |
0.5 W | |
24 | 21 mA | 1,150 Ω | ||||||
100/110 | 5 mA | 20,000 Ω | 80% max. of rated value |
10% min. of rated value |
110% of rated value |
0.5 W |
Classification | For input | For output | ||
---|---|---|---|---|
Resistive load (cosΦ = 1) |
Inductive load (L/R = 7 ms) |
Resistive load (cosΦ = 1) |
Inductive load (cosΦ = 0.4, L/R = 7 ms) |
|
Contact mechanism | Crossbar bifurcated | Single | ||
Contact material | AgAu-clad Ag | AgSnIn | ||
Rated load | 1 A at 24 VDC | 0.5 A at 24 VDC | 5 A at 24 VDC 2 A at 220 VAC |
2 A at 24 VDC 1 A at 220 VAC |
Rated carry current | 1 A | 5 A | ||
Max. switching voltage | 250 VAC, 125 VDC | |||
Max. switching current | 1 A | 5 A | ||
Failure rate (reference value) | 100 μA at 1 VDC | 10 mA at 5 VDC |
Contact resistance (see note 2) | 50 mΩ max. |
---|---|
Operate time (see note 3) | 15 ms max. |
Release time (see note 3) | 15 ms max. |
Max. operating frequency | Mechanical: 18,000 operations/hour Electrical: 1,800 operations/hour (under rated load) |
Insulation resistance (see note 4) | 100 MΩ (at 500 VDC) |
Dielectric strength | Between coil and contacts: 2,000 VAC, 50/60 Hz for 1 minute Between contacts of same polarity: 1,000 VAC, 50/60 Hz for 1 minute |
Vibration resistance | Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) |
Shock resistance | Malfunction: 200 m/s2 |
Mechanical endurance | 50,000,000 operations |
Electrical endurance (see note 5) | Input: 10,000,000 operations (10 mA) or 50,000 operations (1 A) with resistive load 2,500,000 operations (10 mA) or 20,000 operations (1 A) with inductive load Output: 1,000,000 operations with rated load |
Error rate (level P) (Reference value) (see note 6) |
Input: 100 μA at 1 VDC Output: 10 mA at 5 VDC |
Ambient temperature | Operating: -40°C to 70°C (with no icing or condensation) |
Ambient humidity | Operating: 5% to 85% (with no icing or condensation) |
Weight | Approx. 17 g |
Model | P7TF-05 |
---|---|
Contact resistance | 10 mΩ max. |
Dielectric strength | 2,000 VAC for 1 minute |
Insulation resistance | 1,000 MΩ min. (at 500 VDC) |
Vibration resistance | 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) |
Shock resistance | 1,000 m/s2 |
Ambient temperature | Operating:-40°C to 70°C (with no icing or condensation) |
Ambient Humidity | Operating: 5% to 85%RH |
Weight | Approx. 28 g |