G7SA

Category Tag

• Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditional screw terminals.
(Wiring time is reduced by 60%* in comparison with traditional screw terminals.)

• Relays with forcibly guided contacts (EN/IEC 61810-3, Certified by VDE).

• Supports the CE marking of machinery (Machinery Directive).

• Helps avoid hazardous machine status when used as part of an interlocking circuit.

• Four-pole and six-pole Relays are available.

• The Relay’s terminal arrangement simplifies PWB pattern design.

• Reinforced insulation between inputs and outputs. Reinforced insulation between some poles of different polarity.

Ratings

Safety Relay Unit

Coil (4 poles)

 

Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW)
Rated voltage
12 VDC 30 400 110% Approx. 360
18 VDC 20 900
21 VDC 17.1 1,225
24 VDC 15 1,600
48 VDC 7.5 6,400
110 VDC 3.8 28,810 Approx. 420

 

Coil (6 poles)

 

Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW)
Rated voltage
12 VDC 41.7 288 110% Approx. 500
18 VDC 27.8 648
21 VDC 23.8 882
24 VDC 20.8 1,152
48 VDC 10.4 4,606
110 VDC 5.3 20,862 Approx. 580

 

Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.

Contacts

 

Load Resistive load
Rated load 6 A at 250 VAC, 6 A at 30 VDC
Rated carry current 6 A
Max. switching voltage 250 VAC, 125 VDC
Max. switching current 6 A
Contact materials Au plating + Ag alloy

 

Characteristics

Safety Relay Unit

 

Contact resistance *1 100 mΩ max.
Operating time *2 20 ms max.
Response time *3 10 ms max.
Release time *2 20 ms max.
Must operate voltage 75% max.
Must release voltage 10% min.
Maximum
operating
frequency
Mechanical 36,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *4 1,000 MΩ min.
Dielectric
Strength
*5 *6
Between coil
and contacts
4,000 VAC, 50/60 Hz for 1 min.
Between
contacts of
different olarity
4,000 VAC, 50/60 Hz for 1 min. (except for followings)
4 poles (for poles 3-4 in 4-pole Relays),
6 poles (for poles 3-5, 4-6, and 5-6 in 6-pole Relays): 2,500 VAC, 50/60 Hz for 1 min.
Between
contacts of the
same polarity
1,500 VAC, 50/60 Hz for 1 min.
Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 100 m/s2
Durability
*7
Mechanical 10,000,000 operations min. (at approx. 36,000 operations/h)
Electrical 100,000 operations min. (at the rated load)
Inductive load switching
capability *8
(IEC60947-5-1)
AC15 240 VAC, 2 A
DC13 24 VDC, 1 A/48 VDC, 0.5 A/110 VDC, 0.2 A
Failure rate (P level)
(reference value *9)
5 VDC, 1 mA
Ambient operating
temperature *10
12 to 48 VDC: -40 to 85°C (with no icing or condensation)
110 VDC: -40 to 60°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight 4 poles: Approx. 22 g
6 poles: Approx. 25 g

 

 

Note: 1. The above values are initial values.
2. Performance characteristics are based on coil temparature of 23°C.
*1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
*2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not
included.
*3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.
Contact bounce time is included. Measurement conditions: Rated voltage operation, Ambient temperature: 23°C
*4. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric
strength was measured.
*5. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and
pole 6 refers to terminals 63-64.
*6. When using a P7SA Socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for
1 min. When using Push-In Plus terminal sockets (P7SA-[]F-ND-PU), the dielectric strength between coil contacts
as well as between different poles is 4,000 VAC, 50/60 Hz for 1 min.
*7. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%. For the durability
performance to the load, refer to the Durability Curve.
*8. AC15: cosφ = 0.3, DC13: L/R = 48-ms.
*9. The failure rate is based on an operating frequency of 300 operations/min.
*10. 12 to 48 VDC:
When operating between 70 and 85°C, reduce the rated carry current of 6 A by 0.1 A for each degree above 70°C.
110 VDC:
When operating between 40 and 60°C, reduce the rated carry current of 6 A by 0.27 A for each degree above 40°C.

 

Options (order separately)

Sockets

 

Model Push-In Plus terminals Screw terminals PCB terminals
4 poles 6 poles 4 poles 6 poles 4 poles 6 poles
P7SA-10F-ND-PU P7SA-14F-ND-PU P7SA-10F(-ND) P7SA-14F(-ND) P7SA-10P P7SA-14P
Ambient operating temperature • With operation indicator LED/built-in diode
P7SA-[]F-ND(-PU): -20 to +70°C
• Without operation indicator LED/built-in diode
P7SA-[]F: -40 to +85°C
(with no icing or condensation)
-40 to +85°C
(with no icing or condensation)
Ambient operating humidity 25% to 85% 5% to 85%
Continuous carry current 6 A *1
Dielectric
strength
Between coil
and contact
terminals
4,000 VAC for 1 min. 2,500 VAC for 1 min.
Between contact
terminals of
different polarity
2,500 VAC for 1 min.
Between contact
terminals of
same polarity
1,500 VAC for 1 min.
Insulation resistance 1,000 MΩ min. *2
Weight Approx. 58 g Approx. 70 g Approx. 44 g Approx. 59 g Approx. 9 g Approx. 10 g

 

*1. When operating the P7SA-[]F-ND-PU at a temperature between 50 and 70°C, reduce the continuous current
(6 A at 50°C or less) by 0.25 A for each degree above 50°C.
When operating the P7SA-[]F-ND at a temperature between 50 and 70°C, reduce the continuous current
(6 A at 50°C or less) by 0.3 A for each degree above 50°C.
When operating the P7SA-[]F at a temperature between 50 and 85°C, reduce the continuous current
(6 A at 50°C or less) by 0.1 A for each degree above 50°C.
*2. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.

Short Bars (for P7SA-[]F-ND-PU)

 

Application Applicable
sockets
Models Maximum
carry current
Ambient operating
temperature
Ambient operating
humidity
Crossover wiring of
contact terminals
(bottom)
P7SA-[]F-ND-PU XW5S-P2.5-2[] 24 A -40 to 55°C 5% to 95%