• Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model.
• Dedicated, compact aluminum PCB and power elements used.
• Built-in varistor effectively absorbs external surges.
• Quick-connect #110 input terminals and #250 output connections. (#187 input terminals and #250 output connections are available.)
• “-US” models certified by UL, CSA, and IEC/EN (TÜV).
Rated voltage |
Operating voltage | Voltage level | Input impedance | ||
---|---|---|---|---|---|
Must operate | Must release | With zero cross function |
Without zero cross function |
||
5 VDC | 4 to 6 VDC | 4 VDC max. | 1 VDC min. | 250 Ω±20% | 300 Ω±20% |
12 VDC | 9.6 to 14.4 VDC | 9.6 VDC max. | 600 Ω±20% | 800 Ω±20% | |
24 VDC | 19.2 to 28.8 VDC | 19.2 VDC max. | 1.6 kΩ±20% |
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Model | Applicable load | ||||
---|---|---|---|---|---|
Rated load voltage |
Load voltage range |
Load current (See note 1.) |
Inrush current | ||
With heat sink | Without heat sink | ||||
G3NE-205T(L)(-2)-US | 100 to 240 VAC | 75 to 264 VAC | 0.1 to 5 A at 40 ° C |
0.1 to 5 A at 40 ° C |
60 A (60 Hz, 1 cycle) |
G3NE-210T(L)(-2)-US | 0.1 to 10 A at 40 ° C (See note 2.) |
0.1 to 5 A at 40 ° C |
150 A (60 Hz, 1 cycle) |
||
G3NE-220T(L)(-2)-US | 0.1 to 20 A at 40 ° C (See note 2.) |
0.1 to 5 A at 40 ° C |
220 A (60 Hz, 1 cycle) |
Item | G3NE-2[][]T(-2)-US | G3NE-2[][]TL(-2)-US |
---|---|---|
Operate time | 1/2 of load power source cycle + 1 ms max. | 1 ms max. |
Release time | 1/2 of load power source cycle + 1 ms max. | |
Output ON voltage drop | 1.6 V (RMS) max. | |
Leakage current | 2 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) |
|
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min | |
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | |
Shock resistance | Destruction: 1,000 m/s2 | |
Ambient temperature | Operating: -30°C to 80°C (with no icing or condensation) Storage: -30°C to 100°C (with no icing or condensation) |
|
Ambient humidity | Operating: 45% to 85% | |
Certified standards | UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535 TÜV R9051064 (VDE0435) (EN60950) |
|
EMC | Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 |
|
Weight | Approx. 37 g |