G3H / G3HD

Category Tag

• Reduces wiring work by 60% when combined with the PTF-08-PU Push-In Plus Terminal blocks (according to actual OMRON measurements).

• Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).

• Socket type, same size as LY Power Relays.

• Operation indicator provided to confirm input (models numbers with “N” before the suffix).

Ratings (at an Ambient Temperature of 25°C)

Input

 

Model Rated voltage Operating voltage Impedance Voltage level
Must operate
voltage
Must release
voltage
G3H-203SN-VD 5 to 24 VDC 4 to 28 VDC 15 mA max.
(See note 2.)
4 VDC max. 1 VDC min.
G3H-203SLN-VD 5 VDC 4 to 6 VDC 390 Ω±20% 4 VDC max. 1 VDC min.
12 VDC 9.6 to 14.4 VDC 900 Ω±20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 2 kΩ±20% 19.2 VDC max.
G3HD-X03SN-VD 5 to 24 VDC 4 to 28 VDC 1.5 kΩ +20%/-10%
(See note 1.)
4 VDC max. 1 VDC min.
G3H-203S-VD 4 to 24 VDC 3 to 28 VDC 15 mA max.
(See note 2.)
3 VDC max. 1 VDC min.
G3H-203SL-VD 5 VDC 4 to 6 VDC 390 Ω±20% 4 VDC max. 1 VDC min.
12 VDC 9.6 to 14.4 VDC 900 Ω±20% 9.6 VDC max.
24 VDC 19.2 to 28.8 VDC 2 kΩ±20% 19.2 VDC max.
G3HD-X03S-VD 4 to 24 VDC 3 to 28 VDC 1.5 kΩ +20%/-10%
(See note 1.)
3 VDC max. 1 VDC min.
G3HD-202SN-VD 12 to 24 VDC 9.6 to 28.8 VDC 25 mA max.
(at 24 VDC)
(See note 2.)
9.6 VDC max. 1 VDC min.

 

 

Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for
Solid State Relays.
2. With constant current input system.

 

Output

 

Model Applicable load
Rated load voltage Load voltage range Load current Inrush current
G3H-203SN-VD
G3H-203S-VD
100 to 240 VAC 75 to 264 VAC 0.1 to 3 A at 40°C 45 A 60 Hz, 1 cycle
G3H-203SLN-VD
G3H-203SL-VD
G3HD-X03SN-VD
G3HD-X03S-VD
4 to 48 VDC 3 to 52.8 VDC 0.1 to 3 A at 40°C 18 A (10 ms)
G3HD-202SN-VD 24 to 240 VDC 19.2 to 264 VDC 0.001 to 2.5 A at 40°C 20 A (10 ms)

 

Characteristics

 

Model G3H-203SN-VD/
203S-VD
G3H-203SLN-VD/
203SL-VD
G3HD-X03SN-VD/
X03S-VD
G3HD-202SN-VD
Operate time 1/2 cycle of load power
source + 1 ms max.
1 ms max. 0.5 ms max. 5 ms max.
Release time 1/2 cycle of load power source + 1 ms max. 2 ms max. 10 ms max.
Output ON voltage
drop
1.6 V (RMS) max. 3 V max. (output
ON-resistance:
1.25 V max.)
Leakage current 5 mA max. (at 100 VAC);
10 mA max. (at 200 VAC)
2.5 mA max. (at 100 VAC);
5 mA max. (at 200 VAC)
5 mA max.
(at 50 VDC)
0.1 mA max.
(at 200 VDC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock resistance Destruction: 1,000 m/s2
Ambient temperature Operating: -30°C to 80°C (with no icing)
Storage: -30°C to 100°C (with no icing)
Ambient humidity 45% to 85%
Certified standards UL (File No.E64562), CSA (File No.LR35535)
VDE (Certificate No.40000159, EN60947-4-3 (G3H-VD)
No.40046471, EN62314 (G3HD-VD (except for G3HD-202SN-VD))
No.40012875, EN62314 (G3HD-202SN-VD))
EMC Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
Weight Approx. 50 g

 

Accessories (Order Separately)

Socket Characteristics

 

   

Model Rated
carry current
Dielectric strength Insulation
resistance *1
Remarks
PTF-08-PU 10 A Between contact terminals of different polarity: 2,000 VAC, 1 min 1,000 MΩ min.
Between contact terminals of same polarity: 2,000 VAC, 1 min
Between coil and contact terminals: 2,000 VAC, 1 min
PTFZ-08-E 12 A ([]70°C)
*2
Between contact terminals of different polarity: 2,500 VAC, 1 min 1,000 MΩ min.
Between contact terminals of same polarity: 2,500 VAC, 1 min
Between ground terminals: 2,500 VAC, 1 min
Between coil and contact terminals: 2,500 VAC, 1 min
PTF08A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT-08 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT08-0 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT08QN 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.