BE60 Digital True RMS Multimeter with Integrated Thermal Imaging Camera

Category Tag

True RMS digital multimeter with integrated BE60 thermal imaging camera

Bluetooth® digital multimeter with eleven measurement functions, IR thermal imaging camera and free smartphone app for the acquisition/evaluation of the measurement data

TECHNICAL DATA
General information
Article number 3.510.205.260
DC voltage [V/DC]
Min. measuring range | DC voltage [V] 0.4
Max. measuring range | DC voltage [V] 600
Accuracy ±[%] (0.4 V) ±(0.8 % +8)
Accuracy ± [%] (4 V / 40 V) | DC voltage ±(0.5 % +5)
Accuracy ± [%] (400 V / 600 V) | DC voltage ±(0.8 % +5)
AC voltage [V/AC]
Min. measuring range | AC voltage [V] 4
Max. measuring range | AC voltage [V] 600
Accuracy ±[%] (4 V/40 V/400 V/600 V) | AC voltage ±(1.0 % +5)
AC voltage [V/AC] + DC voltage [V/DC]
Min. measuring range [V] | AC voltage + DC voltage 4
Max. measuring range [V] | AC voltage + DC voltage 600
Accuracy ±[%] (4 V/40 V/400 V/600 V) | AC voltage + DC voltage ±(2.5 % +20)
Direct current [A/DC]
Min. measuring range | Direct current [µA] 400
Max. measuring range | Direct current [A] 10
Accuracy ±[%] (4000 µA/40 mA/400 mA) ±(1.5 % +5)
Accuracy ± [%] (10 A) | direct current ±(2 % +8)
Accuracy ± [%] (400 mA) | direct current ±(1.5 % +8)
Alternating current [A/AC]
Min. measuring range | Alternating current [A] 400
Max. measuring range | Alternating current [A] 10
Accuracy ± [%] (10 A) | alternating current [A/AC] ±(2.5 % +5)
Accuracy ±[%] (400 µA/4000 µA/0.04 A/0.4 A) ±(2.0 % +5)
Resistance [Ω]
Min. measuring range [Ω] | Resistance 400 Ω
Max. measuring range [Ω] | resistance 40 MΩ
Accuracy ±[%] (400 Ω) ±(1.0 % +10)
Accuracy ± [%] (400 Ω/4 kΩ/40 kΩ/ 400 kΩ/4 MΩ) ±(1.0 % +5)
Accuracy ±[%] (40 MΩ) ±(2.5 % +10)
Capacity [F]
Min. measuring range | Capacity [nF] 40
Max. measuring range | Capacity [uF] 4,000
Accuracy ± [%] (40.00 nF) ±(3.0 % +20)
Accuracy ± [%] (400.0 nF) ±(3.0 % +8)
Accuracy ± [%] (4 µF) ±(3.0 % +8)
Accuracy ± [%] (40 µF) ±(3.0 % +8)
Accuracy ± [%] (4 µF/40 µF/400 µF) ±(3.0 % +8)
Accuracy ± [%] (4.000 µF) ±(3,5 % +20)
Frequency [f]
Type AC mains voltage, by means of test probes [Hz] 40
Type AC mains voltage, by means of test probes [kHz] 10
Type AC mains voltage, by means of test probes 2 Vrms
Type AC mains voltage, by means of test probes (± 0.5 %)
Type electronic circuits, by means of test probes [Hz] 40
Type electronic circuits, by means of test probes [MHz] 10
Type electronic circuits, by means of test probes >2 (@ 20% ÷ 80 % duty cycle) and f<100 kHz
>5 (@ 20% ÷ 80 % duty cycle) and f>100 kHz
Type electronic circuits, by means of test probes ±(0.2 % rdg + 5 digits)
Duty cycle [%]
Min. measuring range [%] | Duty cycle 10
Max. measuring range [%] | Duty cycle 90
Pulse width 100 µs – 100 ms %
Frequency [Hz] 40 Hz – 10 kHz %
Accuracy [%] ± | Duty cycle ±(1.2 % + 2)
Thermal imaging camera
Field of View (FoV) 21° x 21°
Minimum focal length 0.5 m
Spatial resolution (IFOV) [mrad] 4.53
IR resolution [px] 80 x 80
Thermal sensitivity [30 °C] <0.1 °C
NETD [mk] 100
Refresh rate [Hz] 50
Focus fixed
Focal length [mm] 7.5
Focal Plane Array (FPA) Microbolometer, uncooled
Spectral range 8 – 14 µm
Min. measuring range [C°] | thermal imaging camera -20
Max. measuring range [C°] | thermal imaging camera 260
Accuracy [°C] ± (combined) 3 °C or ±3 % of the measured value
(ambient temperature 10 °C – 35 °C, object temperature >0 °C)
Duty cycle [%]
Display
2.4″
Counts 4,000
Measurement rate
Measurement rate 3 Hz
Housing design
Plastics
Interfaces
Connection sockets for 4 mm safety connectors (banana)
Measuring category
CAT IV (600 V)
Safety
EN 61010-2-031
Degree of pollution 2
Overvoltage category 2
Drop test [m] 2
Type of protection
IP40
Power supply
Internal (battery)
Battery type 1 x 3.7 V Li-Ion, 1400 mAh
Ambient conditions
Operation – min. temperature [°C] 5
Operation – max. temperature [°C] 40
Max. humidity range [% r.F.] 80
Dimensions
Length (packaging excluded) [mm] 150
Width (packaging excluded) [mm] 70
Height (packaging excluded) [mm] 46
Weight
(packaging excluded) [kg] 0.285
STANDARD SCOPE OF DELIVERY
Standard scope of delivery
Measuring device
Battery(-ies)
Safety measuring lines with test probes
Operating manual
ASCERTAINABLE MEASURED VALUES AND FUNCTIONS
Internal sensors
AC voltage [V/AC]
DC voltage [V/DC]
Resistance [Ω]
Alternating current [A/AC]
Direct current [A/DC]
Capacity [nF, µF]
Frequency [Hz, kHz, MHz]
External sensors
Temperature [°C]
Functions and features
Diode testing
Continuity test
Polarity indicator
Maximum value display
Max./min. display
Measured value hold function
Automatic measuring range selection
TRUE RMS measurement of direct current, alternating current, DC voltage, AC voltage, capacity, frequency, duty cycle and resistance
Integrated torch
Automatic switch-off
Backlit display
Battery low indication
Indication when exceeding the measuring range
Input impedance
Alternating current behaviour
ACV bandwidth

 standard equipment

 optionally available

 not available