Product type description |
AZ 17-02ZI B1 |
Article number (order number) |
101121963 |
EAN (European Article Number) |
4030661049717 |
eCl@ss number, version 12.0 |
27-27-26-02 |
eCl@ss number, version 11.0 |
27-27-26-02 |
eCl@ss number, version 9.0 |
27-27-26-02 |
ETIM number, version 7.0 |
EC002592 |
ETIM number, version 6.0 |
EC002592 |
Certificates |
BG cULus EAC |
Coding level according to EN ISO 14119 |
High |
Enclosure material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the actuator |
Stainless steel |
Material of the contacts, electrical |
Silver |
Gross weight |
95 g |
Number of safety contacts |
2 |
Safety classification |
Standards |
EN ISO 13849-1 |
Mission time |
20 Year(s) |
B10D Normally-closed contact (NC) |
2,000,000 Operations |
Note (B10D Normally open contact (NO)) |
at 10% Ie and ohmic load |
Mechanical life, minimum |
1,000,000 Operations |
Latching force |
5 N |
Positive break travel |
11 mm |
Positive break force per NC contact, minimum |
17 N |
Actuating speed, maximum |
2 m/s |
Termination |
IDC method of termination |
Cable section, minimum |
1 x 0.75 mm² |
Cable section, maximum |
1 x 1.0 mm², flexible |
Note (Cable section) |
All indications including the conductor ferrules. |
Length of sensor |
30 mm |
Width of sensor |
30 mm |
Height of sensor |
85 mm |
Degree of protection |
IP67 |
Ambient temperature, minimum |
-30 °C |
Ambient temperature, maximum |
+80 °C |
Rated insulation voltage Ui |
250 V |
Rated impulse withstand voltage Uimp |
4 kV |
Operating voltage, maximum |
230 V |
Thermal test current |
10 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
4 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
4 A |
Switching element |
Opener (NC) |
Switching principle |
Slow action |
Scope of delivery |
Slot cover for dust-proof covering of the opening not in use |
Scope of delivery of mounting material |
Tamperproof screws |
Note (General) |
This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules |