Article number: 101161660
Product type designation |
AZ 15 ZVRK-ST |
Article number (order number) |
101161660 |
EAN (European Article Number) |
4030661196282 |
eCl@ss number, version 12.0 |
27-27-26-02 |
eCl@ss number, version 11.0 |
27-27-26-02 |
eCl@ss number, version 9.0 |
27-27-26-02 |
ETIM number, version 7.0 |
EC002592 |
ETIM number, version 6.0 |
EC002592 |
certificates |
MOT cULus CCC |
regulations |
EN ISO 13849-1 EN ISO 14119 ENIEC 60947-5-1 |
Coding level according to EN ISO 14119 |
small amount |
working principle |
electromechanical |
Material of the housing |
Plastic, glass fiber reinforced thermoplastic, self-extinguishing |
Material of contacts, electrical |
Silver |
gross weight |
105g |
Increased detent force |
Yes |
Usable for elevators |
Yes |
Number of cable penetrations |
3 |
Number of safety contacts |
1 |
regulations |
EN ISO 13849-1 |
service life |
20 years |
B 10D normally closed (NC) |
2,000,000 switching cycles |
Mechanical life, minimum |
1,000,000 switching cycles |
cogging force |
30N |
positive opening travel |
8mm |
Positive opening force per NC contact, minimum |
10N |
Actuation speed, maximum |
2m/s |
connection type |
Built-in connector M12, 4-pin, A-coding |
length of the sensor |
30mm |
width of the sensor |
52mm |
height of the sensor |
75mm |
Degree of protection |
IP67 |
ambient temperature, min |
-30℃ |
ambient temperature, max |
+80°C |
Storage and transport temperature, minimum |
-40℃ |
Storage and transport temperature, maximum |
+85°C |
Permissible installation height above sea level, maximum |
2,000m |
storage and transport temperature |
-40 … +85 °C |
Rated insulation voltage U i |
500v |
overvoltage category |
III |
degree of pollution |
3 |
Rated impulse withstand voltage, 4-pin connector |
2.5kV |
Thermal continuous current |
10A |
Conditional rated short-circuit current |
1,000A |
switching element |
normally closed (NC) |
switching principle |
Slow action, positive break opener |
switching frequency |
4,000 /hr |
Voltage, utilization category AC-15 |
230VAC |
Current, utilization category AC-15 |
4 A |
Voltage, utilization category DC-13 |
24Vdc |
Current, utilization category DC-13 |
4 A |
Note, utilization category DC-13 |
4-pin connector |
scope of delivery |
The actuators are not included in the scope of delivery. |