testo 184 G1 – Vibration, humidity and temperature data logger for transport monitoring

SKU 0572 1846 Category
  • Unlimited operating time
  • All in one data logger: PDF measurement data, configuration file and instruction manual
  • Immediate creation of a PDF report directly after connection to a computer
  • Transport monitoring in compliance with GxP, 21 CFR Part 11 and HACCP

AED 1,280.00

Description

With the data loggers testo 184 G1 for shock, humidity and temperature, you can now monitor the transport of sensitive products such as electronics , art, pharmaceuticals or foods over an unlimited operating time. More info on applications (link to tab Applications)

At their destination, a glance at the display or the LEDs tells you whether the configured limit values have been adhered to. In order to obtain detailed information, it is sufficient to connect the logger to a PC – a PDF report is immediately generated with all relevant data. In order for you to be able to work even more efficiently and conveniently with the data loggers, all required files and information are stored directly and securely in the testo 184 G1: Configuration file, instruction manual and PDF report of your recorded data.

The measurement value store of the data logger testo 184 G1 for shock has a capacity of 1000 measurement values, for humidity and temperature 64000 measurement values. The measurement rate is freely selectable from 1 min to 24 h. The battery has a life of 120 days. The temperature data logger testo 184 G1 is supplied by a standard battery which can be exchanged by the user.

testo 184 G1 is compliant with GxP, 21 CFR Part 11 and HACCP. Testo AG is an ISO 9001:2008-certified company, and ensures the adherence to the norms through internal audits as well as accredited external audits.

All advantages at a glance:
1. Clear alarm indication
A glance at the display or the LEDs is enough to know whether limit values have been violated during transport.

2. Easiest operation
testo 184 G1 is intuitively operated, and can be used without special training or previous knowledge: The “Start” button begins data recording. “Stop” ends it.

3. Easiest configuration
In each testo 184 G1, a configuration file is stored, with which the configuration of the testo 184 G1 is childsplay – no download, no installation, no user interface and no additional costs.

4. Convenient readout
A PDF report with the transport data is created immediately on connection of the testo 184 G1 data logger to the USB interface of a computer. This is suitable for long-term archiving according to PDF/A standard.

5. Mobile readout/printout on site
Data transfer from the data logger to a compatible Testo fast printer (option) also functions wirelessly via NFC.

6. IT-safe
The testo 184 G1 data loggers work securely without software installation or download, so that IT problems are triggered neither by the firewall nor the virus scanner.

Delivery Scope

Data logger for shock, humidity and temperature testo 184 G1 for transport monitoring, battery and wall bracket.

Technical data

Temperature – NTC

Measuring range
-20 to +70 °C
Accuracy
±0.5 °C (0 to +70 °C)
±0.8 °C (-20 to +0 °C)
Resolution
0.1 °C
Reaction time
t₉₀ = 30 min
Measuring rate
1 min to 24 h

Humidity – Capacitive

Measuring range
0 to 100 %RH
Accuracy
±1.8 %RH, +3 % of mv (at 25 °C, 5 % to 80 %RH)
±1 %rF/year Drift
±1 %rF Hysterese
±0.03 %RH/K (at 0 to 60 °C)
Resolution
0.1 %RH
Measuring rate
1 min to 24 h

Shock

Measuring range
0 to 27 g
0 to 265 m/s²
Accuracy
±(0.1 g + 5 % of mv)
±1 / 1 / 1 m/s²
Resolution
0.1 g
1 m/s²
Measuring rate
1 s

General technical data

Weight
44 g
Dimensions
40 x 12.5 x 96.5 mm
Operating temperature
-20 to +70 °C
Product-/housing material
ABS
Protection class
IP30
System requirements
Adobe® Acrobat Reader
Product colour
white
Standards
CE 2014/30/EU; DIN EN 61326-1:2013; DIN EN 50581:2013; CFR 21 Part 11 (in use with testo ComSoft CFR-Software); HACCP International
Channels
5 internal
Operating time
Unlimited
Authorizations
CE
Alarm function
via LED and Display
Battery type
Lithium battery CR2450, 3V, exchangeable
Battery life
120 days (at +25 °C and 15 min. meas. cycle)
Display type
segment LCD
Display size
one-line
Display ligthing
no
Display
Interface
USB; NFC
Memory
64,000 measurement values (temperature and humidity); 1,000 measurement values (shock)
Storage temperature
-55 to +70 °C