• Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads.
• No contact chattering for momentary voltage drops up to 50% of rated voltage.
• Withstanding more than 4 kV between contacts that are different in polarity and between the coil and contacts.
• Flame-resistant materials (UL94V-0-qualifying) used for all insulation material.
• Standard models approved by UL and CSA.
Rated voltage | Rated current | Coil resistance | Must-operate voltage |
Must-release voltage |
Max. voltage | Power consumption |
|
---|---|---|---|---|---|---|---|
AC | 24 VAC | 75 mA | — | 75% max. of rated voltage |
15% min. of rated voltage |
110% of rated voltage |
Approx. 1.8 to 2.6 VA |
50 VAC | 36 mA | — | |||||
100 to 120 VAC | 18 to 21.6 mA | — | |||||
200 to 240 VDC | 9 to 10.8 mA | — | |||||
DC | 12 VDC | 167 mA | 72 Ω | 10% min. of rated voltage |
Approx. 2.0 W | ||
24 VDC | 83 mA | 288 Ω | |||||
48 VDC | 42 mA | 1,150 Ω | |||||
100 VDC | 20 mA | 5,000 Ω |
Item | Resistive load (cosΦ = 1) | Inductive load (cosΦ = 0.4) | Resistive load |
---|---|---|---|
Contact mechanism | Double break | ||
Contact material | Ag alloy | ||
Rated load | NO: 25 A at 220 VAC (24 A at 230 VAC) NC: 8 A at 220 VAC (7.5 A at 230 VAC) |
NO: 25 A at 30 VDC NC: 8 A at 30 VDC |
|
Rated carry current | NO: 25 A (1 A) NC: 8 A (1 A) |
||
Max. switching voltage | 250 VAC | 125 VDC | |
Max. switching current | NO: 25 A (1 A) NC: 8 A (1 A) |
Note: The values in parentheses indicate values for a bifurcated contact.
Contact resistance *2 | 100 mΩ max. |
---|---|
Operate time *3 | 50 ms max. |
Release time *3 | 50 ms max. |
Max. operating frequency | Mechanical: 1,800 operations/hr Electrical: 1,800 operations/hr |
Insulation resistance *4 | 1,000 MΩ min. (at 500 VDC) |
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 4,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 2,000 VAC, 50/60 Hz for 1 min between contacts of same polarity |
Impulse withstand voltage | 10,000 V between coil and contact (with 1.2 x 50 μs impulse wave) |
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: NO: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) NC: 10 to 26 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
Shock resistance | Destruction: 1,000 m/s2 Malfunction: NO: 100 m/s2, NC: 20 m/s2 |
Endurance | Mechanical: 1,000,000 operations min. (at 1,800 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr) *5 |
Error rate *6 | 100 mA at 24 VDC (bifurcated contact: 24 VDC 10 mA) |
Ambient temperature | Operating: -25°C to 60°C (with no icing or condensation) |
Ambient humidity | Operating: 5% to 85% |
Weight | PCB terminal: approx. 140 g Screw terminal: approx. 165 g Quick-connect terminal:approx. 140 g |