• Reduces wiring work by 60% when combined with the PFY-08-PU Push-In Plus Socket (according to actual OMRON measurements).
• Shape-compatible with mechanical relays.
• Certified by UL, CSA, and VDE (model numbers with a suffix of “-VD”).
• Socket type, same size as MY Power Relays.
• Operation indicator provided to confirm input (model numbers with “N” before the suffix).
Model | Rated voltage | Operating voltage | Impedance | Voltage level | |
---|---|---|---|---|---|
Must operate voltage |
Must release voltage |
||||
G3F-203SN-VD | 5 to 24 VDC | 4 to 28 VDC | 15 mA max. (See note.) |
4 VDC max. | 1 VDC min. |
G3F-202SN-VD | 100/110 VAC | 75 to 125 VAC | 41 kΩ±20% | 75 VAC max. | 20 VAC min. |
200/220 VAC | 150 to 250 VAC | 72 kΩ±20% | 150 VAC max. | 40 VAC min. | |
G3F-203SLN-VD | 5 VDC | 4 to 6 VDC | 390 Ω±20% | 4 VDC max. | 1 VDC min. |
12 VDC | 9.6 to 14.4 VDC | 900 Ω±20% | 9.6 VDC max. | ||
24 VDC | 19.2 to 28.8 VDC | 2 kΩ±20% | 19.2 VDC max. | ||
G3FD-X03SN-VD | 5 to 24 VDC | 4 to 28 VDC | 1.5 kΩ+20%/-10% | 4 VDC max. | |
G3FD-102SN-VD | 5 to 24 VDC | 4 to 28 VDC | 1.5 kΩ+20%/-10% | 4 VDC max. | |
100/110 VAC | 75 to 125 VAC | 41 kΩ±20% | 75 VAC max. | 20 VAC min. | |
200/220 VAC | 150 to 250 VAC | 72 kΩ±20% | 150 VAC max. | 40 VAC min. | |
G3F-203S-VD | 4 to 24 VDC | 3 to 28 VDC | 15 mA max. (See note.) |
3 VDC max. | 1 VDC min. |
G3F-203SL-VD | 5 VDC | 4 to 6 VDC | 390 Ω±20% | 4 VDC max. | |
12 VDC | 9.6 to 14.4 VDC | 900 Ω±20% | 9.6 VDC max. | ||
24 VDC | 19.2 to 28.8 VDC | 2 kΩ±20% | 19.2 VDC max. | ||
G3FD-X03S-VD | 4 to 24 VDC | 3 to 28 VDC | 1.5 kΩ+20%/-10% | 3 VDC max. | |
G3FD-102S-VD |
Model | Rated load voltage |
Applicable load | ||
---|---|---|---|---|
Load voltage range |
Load current | Inrush current |
||
G3F-203SN-VD G3F-203SLN-VD G3F-203S-VD G3F-203SL-VD |
100 to 240 VAC | 75 to 264 VAC | 0.1 to 3 A at 40 ° C | 45 A (60 Hz, 1 cycle) |
G3F-203SN-VD | 100 to 240 VAC | 75 to 264 VAC | 0.1 to 2 A at 40 ° C | 45 A (60 Hz, 1 cycle) |
G3FD-X03SN-VD G3FD-X03S-VD |
4 to 48 VDC | 3 to 52.8 VDC | 0.1 to 3 A at 40 ° C | 18 A (10 ms) |
G3FD-102SN-VD G3FD-102S-VD |
5 to 110 VDC | 3 to 125 VDC | 0.1 to 2 A at 40 ° C | 10 A (10 ms) |
Item | G3F-203SN-VD G3F-202SN-VD G3F-203S-VD |
G3F-203SLN-VD G3F-203SL-VD |
G3FD-X03SN-VD G3FD-X03S-VD |
G3FD- 102SN-VD |
G3FD- 102S-VD |
---|---|---|---|---|---|
Operate time | 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) |
1 ms max. | 0.5 ms max. | 0.5 ms max. (DC input) 20 ms max. (AC input) |
0.5 ms max. |
Release time | 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) |
1/2 of load power source cycle + 1 ms max. |
2 ms max. | 2.5 ms max. (DC input) 20 ms max. (AC input) |
2.5 ms max. |
Output ON voltage drop | 1.6 V (RMS) max. | 1.5 V max. | |||
Leakage current | 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) |
2.5 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) |
5 mA max. (at 50 VDC) |
0.1 mA max. (at 100 VDC) |
0.1 mA max. (at 100 VDC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min | 1,500 VAC, 50/60 Hz for 1 min | |||
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | ||||
Shock resistance | Destruction: 1,000 m/s2 | ||||
Ambient temperature | Operating: -30°C to 80°C (with no icing or condensation) Storage: -30°C to 100°C (with no icing or condensation) |
||||
Ambient humidity | Operating: 45% to 85% | ||||
Certified standards | UL (File No.E64562), CSA (File No.LR35535) VDE (Certificate No.40000159, EN60947-4-3 (G3F-VD) No.40046471, EN62314 (G3FD-VD) |
||||
EMC | Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 |
||||
Weight | Approx. 50 g |