• Shape-compatible with mechanical relays.
• Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
• Plug-in type, same size as MK Power Relays.
• Operation indicator provided to confirm input.
• DC Output model available with 3 to 125-VDC load voltage range for high-voltage applications.
Model | Rated voltage | Operating voltage | Input current | Voltage levels | |
---|---|---|---|---|---|
Must operate voltage |
Must release voltage |
||||
G3B-205S-VD | 5 to 24 VDC | 4 to 30 VDC | 15 mA max. (See note.) |
4 VDC max. | 1 VDC min. |
G3BD-103S-VD | 1.5 kΩ+20%/-10% |
Model | Applicable load | |||
---|---|---|---|---|
Rated load voltage | Load voltage range | Load current | Inrush current | |
G3B-205S-VD | 100 to 240 VAC | 75 to 264 VAC | 0.1 to 5 A at 40 ° C | 80 A, 60 Hz for 1 cycle |
G3BD-103S-VD | 5 to 110 VDC | 3 to 125 VDC | 0.1 to 3 A at 40 ° C | 12 A (10 ms) |
Model | G3B-205S-VD | G3BD-103S-VD |
---|---|---|
Operate time | 1/2 cycle of load power source + 1 ms max. | 0.5 ms max. |
Release time | 1/2 cycle of load power source + 1 ms max. | 2.5 ms max. |
Output ON voltage drop | 1.6 V (RMS) max. | 1.5 V max. |
Leakage current | 5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) | 5 mA max. (at 125 VDC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min | 1,500 VAC, 50/60 Hz for 1 min |
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | |
Shock resistance | 1,000 m/s2 | |
Ambient temperature | Operating: -30°C to 80°C (with no icing or condensation) Storage: -30°C to 100°C (with no icing or condensation) |
|
Ambient humidity | 45% to 85% | |
Certified standards | UL (File No.E64562), CSA (File No.LR35535) VDE (Certificate No.40000157, EN60947-4-3 (G3B-VD) No.40046587, EN62314 (G3BD-VD)) |
|
EMC | Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 |
|
Weight | Approx. 70 g |