G3NE

Category Tag

• Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model.

• Dedicated, compact aluminum PCB and power elements used.

• Built-in varistor effectively absorbs external surges.

• Quick-connect #110 input terminals and #250 output connections. (#187 input terminals and #250 output connections are available.)

• “-US” models certified by UL, CSA, and IEC/EN (TÜV).

Ratings (at an Ambient Temperature of 25°C)

Input

 

Rated
voltage
Operating voltage Voltage level Input impedance
Must operate Must release With zero cross
function
Without zero cross
function
5 VDC 4 to 6 VDC 4 VDC max. 1 VDC min. 250 Ω±20% 300 Ω±20%
12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 600 Ω±20% 800 Ω±20%
24 VDC 19.2 to 28.8 VDC 19.2 VDC max. 1.6 kΩ±20%

 

Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.

Output

 

Model Applicable load
Rated load
voltage
Load voltage
range
Load current
(See note 1.)
Inrush current
With heat sink Without heat sink
G3NE-205T(L)(-2)-US 100 to 240 VAC 75 to 264 VAC 0.1 to 5 A
at 40 ° C
0.1 to 5 A
at 40 ° C
60 A
(60 Hz, 1 cycle)
G3NE-210T(L)(-2)-US 0.1 to 10 A
at 40 ° C
(See note 2.)
0.1 to 5 A
at 40 ° C
150 A
(60 Hz, 1 cycle)
G3NE-220T(L)(-2)-US 0.1 to 20 A
at 40 ° C
(See note 2.)
0.1 to 5 A
at 40 ° C
220 A
(60 Hz, 1 cycle)

 

 

Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature
under Engineering Data for details on Data Sheet.
2. These values apply when using a dedicated heat sink or a radiation plate of specified size.

 

Characteristics

 

Item G3NE-2[][]T(-2)-US G3NE-2[][]TL(-2)-US
Operate time 1/2 of load power source cycle + 1 ms max. 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop 1.6 V (RMS) max.
Leakage current 2 mA max. (at 100 VAC)
5 mA max. (at 200 VAC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock resistance Destruction: 1,000 m/s2
Ambient temperature Operating: -30°C to 80°C (with no icing or condensation)
Storage: -30°C to 100°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Certified standards UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535
TÜV R9051064 (VDE0435) (EN60950)
EMC Emission: EN55011 Group 1 Class B
Immunity: EN61000-6-2
Weight Approx. 37 g