PROTECT-IE-11-SK

  • Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emergency stop devices, interlocking devices and others
  • 2 safety contacts

Ordering data

Product type description

PROTECT-IE-11-SK

Article number (order number)

101189095

EAN (European Article Number)

4250116202232

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Available until

31.12.2024

Approvals – Standards

Certificates

cULus

EAC

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Enclosure material

Glass-fibre reinforced thermoplastic, ventilated

Gross weight

140 g

General data – Features

Stop-Category

0

Electronic Fuse

Yes

Wire breakage detection

Yes

Cross-circuit detection

Yes

Removable Terminals

Yes

Automatic reset function

Yes

Earth connection detection

Yes

Integral system diagnostics, general

Yes

Number of auxiliary contacts

1

Number of LEDs

5

Number of normally closed (NC)

1

Number of normally open (NO)

1

Number of safety contacts

2

Safety classification
Standards

EN IEC 60947-5-1

EN IEC 61508

Safety classification – Relay outputs
Performance Level, up to

d

Category

3

Diagnostic Coverage (DC) Level

60 %

PFH value

2.00 x 10⁻⁷ /h

Notice

for max. 36,500 switching cycles/year and max. 60% contact load

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data – Connection technique

Termination

Screw connection, plug-in

Terminal designations

IEC/EN 60947-1

Cable section, minimum

0.14 mm²

Cable section, maximum

1.5 mm²

Mechanical data – Dimensions

Width

48 mm

Height

126 mm

Depth

61 mm

Ambient conditions

Degree of protection of the enclosure

IP20

Degree of protection of the mounting space

IP20

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-40 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations

10…55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions – Insulation values

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Rated operating voltage

24 VDC -15% / +20%, residual ripple max. 10 %

Rated AC voltage for controls at DC minimum

20.4 VDC

Rated control voltage at DC, maximum

28.8 VDC

Electrical power consumption

1.7 W

Input resistance at Ue

2,900 Ω

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of “emergency stop”, maximum

20 ms

Pull-in delay at automatic start, maximum

20 ms

Electrical data – Safe relay outputs

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

2 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

24 VAC

Switching capacity, maximum

2 A

Electrical data – Digital inputs

Input signal, HIGH Signal “1”

19 – 28,8 VDC

Input signal, LOW Signal “0”

0 – 1 VDC

Conduction resistance, maximum

40 Ω

Electrical data – Digital Output

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.1 A

Electrical data – Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

0.1 A

Electrical data – Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Position relay K2

Position relay K1

Position relay K3

Position relay K3