• An incredibly small limit switch with a direct opening mechanism (four-contact construction model).
• High-sensitivity safety limit switch.
• Built-in switches with two- or four-contact construction are available.
• Degree of protection: IP67
• Conforms to EN115-1, EN81-1 and EN81-2. (slow-action models only)
• Certified standards: UL, EN (TÜV), and CCC
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certification body | Standards | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) |
*1 |
UL *2 | UL508 CSA C22.2 No.14 |
E76675 |
CQC (CCC) *3 | GB/T14048.5 | *1 |
*1. Contact your OMRON sales representative.
*2. Certification has been obtained for CSA C22.2 No. 14 under UL.
*3. Ask your OMRON representative for information on certified models.
Item | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 0.75 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC |
2.5 A | 15 7.5 |
1.5 0.75 |
1,800 | 180 |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
125 VDC 250 VDC |
2.5 A | 0.55 0.27 |
0.55 0.27 |
69 | 69 |
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 10,000,000 times min. |
Electrical | 1,000,000 times min. (4 mA resistive load at 24 VDC, 4 circuits) 150,000 times min. (1 A resistive load at 125 VAC, 2 circuits/4 mA resistive load at 24 VDC, 2 circuits) *3 |
|
Operating speed | 1 mm/s to 0.5 m/s | |
Operating frequency | Mechanical | 120 operations/minute |
Electrical | 30 operations/minute | |
Contact resistance *5 | 300 mΩ max. (with 1 m cable), 500 mΩ max. (with 3 m cable), 700 m Ωmax. (with 5 m cable) |
|
Minimum applicable load *4 | 4 mA resistive load at 24 VDC, 4 circuits (N-level reference value) | |
Rated insulation voltage (Ui) | 250 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class I (with a ground wire) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity |
2.5 kV |
Between terminals of different polarity |
4 kV | |
Between each terminal and ground |
4 kV | |
Insulation resistance | 100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals of different polarities, between current-carrying metal parts and grounds, and between each terminal and non-current carrying metal parts |
|
Contact gap | 2 × 2 mm min. | |
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 2.5 A (EN60947-5-1) | |
Ambient operating temperature | – 30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Cable | UL2464 No. 22 AWG, finishing O.D.: 8.3 mm | |
Weight | Approx. 190 g (D4F-102-1R, with 1 m cable) Approx. 220 g (D4F-120-1R, with 1 m cable) |