• Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and 3NC contact forms.
(Slow-action models with MBB contacts are available.)
• M12-connector models are also available, saving on labor and simplifying replacement.
• Can be used with both standard loads and microloads.
• Conforms to the requirements for safety contacts in EN 115-1, EN 81-20, and EN 81-50 (slow-action models only).
• Certified standards: UL, EN (TÜV), and CCC
• Machinery Directive
• Low Voltage Directive
• EN50047
• EN60204-1
• EN ISO 14119
• GS-ET-15
Certification body | Standards | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) |
*1 |
UL *2 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) *3 | GB/T14048.5 | *1 |
*1. Consult your OMRON representative for details.
*2. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*3. Ask your OMRON representative for information on certified models.
Item | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 3 A | 0.27 A |
Rated operating voltage (Ue) | 240 V | 250 V |
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch.
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 10 A | 60 | 6 | 7,200 | 720 |
240 VAC | 30 | 3 |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
125 VDC | 2.5 A | 0.55 | 0.55 | 69 | 69 |
250 VDC | 0.27 | 0.27 |
Degree of protection *1 | IP67 (EN60947-5-1) | |
---|---|---|
Durability *2 | Mechanical | 15,000,000 operations min. *5 |
Electrical | 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) |
|
Operating speed | 1 to 500 mm/s (D4N-1120) | |
Operating frequency | 30 operations/minute max. | |
Contact resistance | 25 mΩ max. | |
Minimum applicable load *4 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 300 V | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity | 2.5 kV |
Between terminals of different polarity |
4 kV | |
Between each terminal and non- current carrying metallic parts |
6 kV | |
Insulation resistance | 100 MΩ min. | |
Contact gap | Snap-action: 2 × 0.5 mm min. Slow-action: 2 × 2 mm min. |
|
Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
Shock resistance | Destruction | 1,000 m/s2 min. |
Malfunction | 300 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
Ambient operating temperature | -30 to 70°C (with no icing) | |
Ambient operating humidity | 95% max. | |
Weight | Approx. 82 g (D4N-1120) Approx. 99 g (D4N-6120) |