• Incorporation of plastic rod actuator makes the Switch easy on hands.
• One-way operation:
Equipped with stopper so that operation is only possible from one direction.
• Distinctive yellow used for the body.
• Three different types of mounting are available.
• Models with emergency-stop switch are available to suit the application.
Agency | Standard | File No. |
---|---|---|
CCC (CQC) | GB/T14048.5 | Contact your OMRON representative for details. |
Applicable category and ratings |
---|
AC-15 3A/240V DC-13 0.27A/250V |
Rated voltage | Carry current | Current (A) | Volt-amperes (V) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC 240 VAC |
10 A | 60 30 |
6 3 |
7,200 | 720 |
125 VDC 250 VDC |
2.5 A | 0.55 0.27 |
0.55 0.27 |
69 | 69 |
Degree of protection *1 | IP65 | ||
---|---|---|---|
Vibration resistance | Malfunction: 10 to 55 Hz, 0.65-mm single amplitude, 100 m/s2 max. | ||
Shock resistance |
Destruction | 1,000 m/s2 max. | |
Malfunction | 20 m/s2 max. | ||
Operating environment |
Ambient operating temperature | -10 ° C to +70 ° C | |
Ambient operating humidity | 35% to 95%RH | ||
Built-in switch specifications |
Switch model | D4N-2187 | |
Allowable operating speed | 1 mm/s to 0.5 m/s | ||
Allowable operating frequency |
Mechanical | 60 operations/min | |
Electrical | 30 operations/min (with resistive load) | ||
Durability *2 | Mechanical | 1,000,000 operations min. | |
Electrical | 200,000 operations min. (for a resistive load of 10 A at 125 VAC) | ||
Contact type | SPST-NO+SPST-NC | ||
Terminal type | Screw terminals | ||
Emergency- stop switch specifications |
Switch model | A165E-M-02 | |
Operating method | Slow action, Direct-opening mechanism | ||
Operating functions | Push to lock, turn to reset Contact is opened by pushing in switch and closed by returning switch to original position. |
||
Contact type | DPST-NC | ||
Operating part | Size: 40 dia. Color: red, non-illuminated | ||
Terminal type | Soldered terminals |