General-purpose Limit Switch HL-5000

Categories , Tag

• The Head, Box, and Cover mate with ridged surfaces to maintain strength.

• A unique Head structure provides a large OT for smooth operation.

• Easy-to-wire conduit opening design.

• Ideal for application in printing machines, forming machines,and light machines.
(High Switches with high sealing characteristics, such as WL or D4C Switches, in locations subject to oil, water, or precipitation.)

• Models with grounding terminals conform to the CE marking.

• Approved by CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)

Approved Standards

 

Agency Standard File No.
CCC (CQC) GB/T14048.5 Contact your OMRON representative for details.

 

Note: Ask your OMRON representative for information on approved models.

Ratings

 

Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5
5
1.5
1
0.7
0.5
3
3
2
1.5
1
0.8
12 VDC
24 VDC
125 VDC
250 VDC
5
5
3
3
4
4
3
3
0.4
0.4
0.2
0.2

 

 

Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.

 

 

Inrush current NC 24 A max.
NO 12 A max.

 

Approved Standard Ratings

CCC (GB/T14048.5)

 

Applicable category and ratings
AC-15 3 A/250 VAC

 

Characteristics

 

Degree of protection IP65
Durability * Mechanical 10,000,000 operations min. (under rated conditions)
Electrical See the following Electrical Durability.
Operating speed 5 mm/s to 0.5 m/s
Operating frequency Mechanical 120 operations/min
Electrical 30 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part
Rated frequency 50/60 Hz
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature -5°C to +65°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 130 to 190 g