Character Height of 10 mm with a Wide Viewing Angle.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Power supply circuit and input circuits are isolated for safety and reliability.
Previous non-isolated timers had wiring restrictions and could be damaged if wired incorrectly. The H5CZ removes these worries.
You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mistakes.
The output counter counts the number of times the output turns ON (alarm display, count monitoring, count in increments of 1,000). This counter is useful in managing the service life of the Timer or the load.
Models with instantaneous contact outputs have been added for use with self-holding circuits and as auxiliary relays. These models are also convenient when replacing analog timers.
Worry-free application is possible in locations subject to water.
Note: When the Y92S-29 Waterproof Packing is used.
Select from any of seven protection patterns. Use the best one for the application.
Modes, such as a stopwatch mode (Mode S), have been added.
Select any of 15 modes.
Models | H5CZ-L8[] | ||
---|---|---|---|
Ratings | Power supply voltage *1 |
100 to 240 VAC 50/60 Hz 12 to 24 VDC/24 VAC 50/60 Hz |
|
Operating voltage fluctuation range |
85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC) | ||
Power consumption | Approx. 6.2 VA at 100 to 240 VAC, Approx. 5.1 VA/2.4 W at 24 VAC/12 to 24 VDC *2 | ||
Mounting method | Flush mounting, Surface mounting, DIN track mounting | ||
External connections | 8-pin socket | ||
Degree of protection | IEC IP66, UL508 Type 4X (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used 4 digits |
||
Digits | |||
Time ranges | 0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s to 99 min 59 s 0.1 m to 999.9 min, 1 min to 9999 min, 1 min to 99 h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h |
||
Timer mode | Elapsed time (Up), Remaining time (Down) (selectable) | ||
Inputs | Input signals | Signal, Reset (no inputs on models with instantaneous contact outputs) |
|
Input method | No-voltage Input ON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω ) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. |
||
Signal, reset | Minimum input signal width: 1 or 20 ms (selectable, same for all input) | ||
Reset system | Power reset (depending on output mode), External reset, Manual reset, Automatic reset (depending on output mode) |
||
Power reset | Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1, and toff-1 mode) |
||
Reset voltage | 10% max. of rated supply voltage | ||
Sensor waiting time | 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) |
||
Output | Output modes | A: Signal ON Delay I, A-1: Signal ON Delay II, A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat Cycle 1, b-1: Repeat Cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative, Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, toff: Flicker OFF Start 1, ton: Flicker ON Start 1, toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 |
|
Models with Instantaneous Contact Outputs A-2: Power ON Delay I, b: Repeat Cycle 1, E: Interval, Z: ON/OFF-duty- adjustable flicker, toff: Flicker OFF Start 1, ton: Flicker ON Start 1 |
|||
One-shot output time | 0.01 to 99.99 s | ||
Control output | 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Contact materials: AgSnIn |
||
Display method *3 | LCD; Present value: 10-mm-high characters Set value: 6-mm-high characters |
||
Memory backup | EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. | ||
Operating temperature range | -10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation) |
||
Storage temperature range | -25 to 70°C (with no icing or condensation) | ||
Operating humidity range | 25% to 85% | ||
Front panel color | Light gray (5Y7/1) |
Voltage | Applied voltage | Inrush current (peak value) | Time |
---|---|---|---|
100 to 240 VAC | 264 VAC | 5.3 A | 0.4 ms |
12 to 24 VDC/24 VAC | 26.4 VAC | 6.4 A | 1.4 ms |
26.4 VDC | 4.4 A | 1.7 ms |
*3. The display is lit only when the power is ON. Settings and changes are not possible if the power supply is not ON.
Accuracy of operating time and setting error (including temperature and voltage influences) |
Power-ON start: ±0.01% ±50 ms max. *1 Signal start: ±0.005%±0.03 ms max. *1 If the set value is within the sensor waiting time at startup the control output of the H5CZ will not turn ON until the sensor waiting time passes. |
|
---|---|---|
Insulation resistance | 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts | |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits (H5CZ-L8 only) 2,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuits (for all models except H5CZ-L8E[]) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts |
|
Impulse withstand voltage | 5 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC 5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC |
|
Noise immunity | ±1.5 kV (between power terminals) and ±600 V (between input terminals (for all models except H5CZ-L8E[])), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | |
Static immunity | Malfunction: 8 kV Destruction: 15 kV |
|
Vibration resistance |
Destruction | 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each |
Malfunction | 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each | |
Shock resistance |
Destruction | 300 m/s2 in three directions, three cycles |
Malfunction | 100 m/s2 in three directions, three cycles | |
Life expectancy |
Mechanical | 10,000,000 operations min. (under no load at 1,800 operations/h and ambient temperature of 23°C) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h and ambient temperature of 23°C) * 2 |
|
Weight | Approx. 105 g (Timer only) |
*1. The values are based on the set value.
*2. Refer to Life-test Curve.
A maximum current of 0.15 A can be switched at 125 VDC (cosφ =1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected.
Approved safety standards | UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14 *1, conforms to EN61812-1 (Pollution degree 2/overvoltage category III) B300 PILOT DUTY 1/4 HP 120 VAC, 1/3 HP, 240 VAC, 5 A resistive load VDE0106/P100 CCC: GB/T 14048.5 Pollution degree 2, Overvoltage category III *2 |
---|---|
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption: IEC61000-4-11 |
Rated operating voltage Ue Rated operating current Ie |
AC-15: Ue: 250 VAC, Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 0.5 A |
---|---|
Rated insulation voltage | 250 V |
Rated impulse withstand voltage (altitude: 2,000 m max.) |
4 kV (at 240 VAC) |
Conditional short-circuit current | 1000 A |
For details, refer to the timing charts on Data Sheet.
Inputs * | Start signal | Normally functions to start timing. In modes A-2 and A-3, disable timing. In mode S, starts and stops timing. |
---|---|---|
Reset | • Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode, the present value returns to the set value.) • Count inputs are not accepted and control output turns OFF while reset input is ON. • Reset indicator is lit while reset input is ON. |
|
Outputs | Control output (OUT) |
Outputs take place according to designated operating mode when timer reaches corresponding set value. |