• V-series Switches were placed in diecast cases to provide superior dust resistance and mechanical strength.
• Cam arms and cam roller arms can be set to any position within 360°
Rated voltage (V) |
Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 AC 250 |
10 10 |
2 1.5 |
10 10 |
3 2 |
||||
8 DC 14 30 125 250 |
10 10 6 0.6 0.3 |
2 3 3 0.1 0.05 |
6 6 4 0.6 0.3 |
6 6 4 0.1 0.05 |
Inrush current | NC | 24 A max. |
---|---|---|
NO | 24 A max. |
Degree of protection | IP60 | |
---|---|---|
Durability * | Mechanical | 1,500,000 operations min. |
Electrical | 300,000 operations min. (10 A at 250 VAC, resistive load) | |
Operating speed | Sealed plunger: 0.1 mm/s to 0.5 m/s Cam arm: 0.5 mm/s to 0.5 m/s Cam roller arm: 0.5 mm/s to 0.5 m/s |
|
Allowable operating frequency |
Mechanical | 120 operations/min. |
Electrical | 60 operations/min. | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 15 mΩ max. (initial value) | |
Dielectric strength | Between terminals of the same polarity |
1,000 VAC at 50/60 Hz for 1 minute |
Between each terminal and non-current-carrying parts |
1,500 VAC, 50/60 Hz for 1 minute | |
Vibration resistance | Malfunction: 10 to 55 Hz, 1.5-mm double amplitude | |
Shock resistance | Destruction: 1,000 m/s2 max., Malfunction: 300 m/s2 max. | |
Ambient operating temperature | -10°C to 80°C (with no icing) | |
Ambient operating humidity | 35% to 95% | |
Weight | Approx. 120 to 170 g |