Small Enclosed Switches VE

• V-series Switches were placed in diecast cases to provide superior dust resistance and mechanical strength.

• Cam arms and cam roller arms can be set to any position within 360°

Ratings

 

Rated
voltage (V)
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 AC
250
10
10
2
1.5
10
10
3
2
8 DC
14
30
125
250
10
10
6
0.6
0.3
2
3
3
0.1
0.05
6
6
4
0.6
0.3
6
6
4
0.1
0.05

 

 

Inrush current NC 24 A max.
NO 24 A max.

 

 

Note: 1. The above values are continuous currents.
2. Inductive loads have a power factor of 0.4 or higher (AC) or a time constant of 7 ms or lower (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.

 

Characteristics

 

Degree of protection IP60
Durability * Mechanical 1,500,000 operations min.
Electrical 300,000 operations min. (10 A at 250 VAC, resistive load)
Operating speed Sealed plunger: 0.1 mm/s to 0.5 m/s
Cam arm: 0.5 mm/s to 0.5 m/s
Cam roller arm: 0.5 mm/s to 0.5 m/s
Allowable operating
frequency
Mechanical 120 operations/min.
Electrical 60 operations/min.
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value)
Dielectric strength Between terminals of the
same polarity
1,000 VAC at 50/60 Hz for 1 minute
Between each terminal and
non-current-carrying parts
1,500 VAC, 50/60 Hz for 1 minute
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction: 1,000 m/s2 max., Malfunction: 300 m/s2 max.
Ambient operating temperature -10°C to 80°C (with no icing)
Ambient operating humidity 35% to 95%
Weight Approx. 120 to 170 g