Enclosed Switch SHL

• Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved models.)

• Incorporates a switch with a durable coil spring in a tough, highprecision case.

• Compact and uses a single basic switch for applications where strength is required.

• Models for microloads and models with operation indicators added to series.

• Terminal protective cover can be switched to wire cable from either the left or right.

• Sealing characteristics that meet IEC IP67 degree of protection.

Approved Standards

 

Agency Standard File No. Approved models
UL UL508 E76675 General-purpose models listed on Data Sheet.
CSA CSA C22.2 No. 14 LR45746
TÜV Rheinland EN60947-5-1 J50062486 All SHL models listed in this datasheet.
CCC (CQC) GB/T14048.5 Contact your OMRON
representative for details.
Ask your OMRON representative for information
on approved models.

 

Ratings

 

Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
480 VAC
10
10
2
1.5
1.5
3
2
2.5
1.5
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
5
0.4
0.2
2
2
1.5
0.4
0.2
5
5
1.5
0.05
0.03
2
2
1.5
0.05
0.05

 

 

Inrush current NC 15 A max.
NO 15 A max.

 

 

Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.

 

Micro load models

 

Rated voltage Non-inductive load (A)
Resistive load
NC NO
125 VAC 0.1
8 VDC
14 VDC
30 VDC
0.1
0.1
0.1

 

Approved Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T14048.5)

 

Model Category and rating I the
SHL-[]55 AC-15 2 A/125 V
DC-12 2 A/48 V
5 A
5 A
SHL-[]55-01 AC-14 0.1 A/125 V
DC-12 0.1 A/48 V
0.5 A
0.5 A
SHL-[]55-L AC-15 2 A/125 V 5 A
SHL-[]55-01L AC-14 0.1 A/125 V 0.5 A
SHL-[]55-01L2 DC-12 0.1 A/12 V 0.5 A
SHL-[]55-L3 DC-12 2 A/24 V 5 A
SHL-[]55-01L3 DC-12 0.1 A/24 V 0.5 A
SHL-[]55-L4 DC-12 2 A/24 V 5 A
SHL-[]55-01L4 DC-12 0.1 A/24 V 0.5 A
SHL-[]55-L5 DC-12 2 A/48 V 5 A
SHL-[]55-01L5 DC-12 0.1 A/48 V 0.5 A

 

 

Note: “AC-15 2 A/125 V” indicates the following.
Application category: AC-16
Rated operating current (Ie): 2 A
Rated operating voltage (Ue): 125 V

 

UL/CSA

A300

 

Rated voltage Carry current Current (A) Volt-amperes (V)
Make Break Make Break
120 VAC
240 VAC
10 A 60
30
6
3
7,200 720

 

Characteristics (For SHL-W155)

 

Degree of protections *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 10,000,000 operations min.
Electrical 500,000 operations min.
Operating speed 0.1 mm/s to 0.5 m/s (hinge lever models)
Operating
frequency
Mechanical 120 operations/min
Electrical 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value for the built-in switch when tested alone)
Dielectric
strength
Between terminals of the same
polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and
non-current-carrying metal
part
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui) 150 V (EN60947-5-1)
Pollution degree (operating environment) 3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse type gI or gG (IEC60269)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 5 A (EN60947-5-1)
Protection against electric shock Class II (grounding not required with double insulation)
OFF reverse voltage 1,000 VAC max., 300 VDC max. (EN60947-5-1)
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature -10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight *3 Approx. 62 to 72 g