•Wiring time is reduced with two types of wiring methods capable of one-touch attachment and removal.
• A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available)
• Key holding force of 1,300 N.
• It is possible to change the operation key insertion point without detaching the head.
• Drive solenoids directly from the Controller.
• Lockout key to prevent workers from becoming trapped inside the hazardous area.
• The vertical D4SL-N Guard Lock Safety-door Switch can be easily mounted on 40 × 40 mm aluminum frames.
• The plastic material makes the Slide Key suitable for lightweight doors.
• Machinery Directive
• Low Voltage Directive
• EMC Directive
• EN ISO 14119
• EN60947-5-1
• GS-ET-19
Certification body | Standard | File No. |
---|---|---|
TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. |
UL *1 | UL508, CSA C22.2 No.14 | E76675 |
CQC (CCC) | GB/T 14048.5 | Consult your OMRON representative for details. |
KOSHA *2 | EN60947-5-1 | Consult your OMRON representative for details. |
*1. Certification has been obtained for UL CSA C22.2 No. 14.
*2. Only certain models have been certified.
Utilization category | AC-15 | DC-13 |
---|---|---|
Rated operating current (Ie) | 1.5 A *1 1 A *2 |
0.22 A |
Rated operating voltage (Ue) | 120 V | 125 V |
Note: Use a 4 A fuse that conforms to IEC60127 as a short-circuit protection device. This fuse is not included with the switch.
*1. 11-42, 21-52, 21-22
*2. Other terminals
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
120 VAC | 2.5 A | 15 | 1.5 | 1,800 | 180 |
Rated voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
---|---|---|---|---|---|
Make | Break | Make | Break | ||
125 VDC | 1.0 A | 0.22 | 0.22 | 28 | 28 |
Item | 24 VDC |
---|---|
Rated operating voltage (100% ED) | 24 VDC +10%, -15% |
Current consumption * | Power ON: 6-contact type Approx. 6.4 W at 0.26 A 4-contact/5-contact type Approx. 4.8 W at 0.2 A Constant: Approx. 2.6 W (average) at 0.2 A (max.) |
Insulation | Class E (to 120°C) |
Item | LED type |
---|---|
Rated voltage | 24 VDC |
Current consumption | Approx.10 mA |
Color (LED) | Orange |
Interlock type | Type 2 (EN ISO 14119) | |
---|---|---|
Coding level | Low level coded (EN ISO 14119) | |
Degree of protection | IP67 *1 TYPE 4X Indoor use only (UL, CSA) |
|
Durability *2 | Mechanical | 1,000,000 operations min. |
Electrical | 150,000 operations min. (1 A resistance at 125 VAC) *3 | |
Operating speed | 0.05 to 1 m/s | |
Operating frequency | 4- and 5-contact Model: 30 operations minute max. 6-contact Model: 5 operations minute max. |
|
Direct opening force *4 | 60 N min. (EN60947-5-1) | |
Direct opening travel *4 | 15 mm min. (EN60947-5-1) | |
Holding force *5 | 1,300 N min. | |
Contact resistance | 200 mΩ max. | |
Minimum applicable load *6 | 1 mA resistive load at 5 VDC (N-level reference value) | |
Rated insulation voltage (Ui) | 150 V (EN60947-5-1) | |
Rated frequency | 50/60 Hz | |
Protection against electric shock | Class II (double insulation) | |
Pollution degree (operating environment) | 3 (EN60947-5-1) | |
Impulse withstand voltage (Uimp) (EN60947-5-1) |
Between terminals of same polarity | 1.5 kV |
Between terminals of different polarity | 1.5 kV | |
Between other terminals and non-current carrying metallic parts |
2.5 kV | |
Insulation resistance | 100 Ω min. (at 500 VDC) | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 0.35 mm single amplitude |
Shock resistance |
Malfunction | 80 m/s2 min. |
Destruction | 1,000 m/s2 min. | |
Conditional short-circuit current | 100 A (EN60947-5-1) | |
Conventional free air thermal current (Ith) | 2.5A (11-42, 21-52, 21-22) 1A (Others) |
|
Ambient operating temperature | -10 to 55°C (with no icing) | |
Ambient operations humidity | 95% max. | |
Weight | Head: Resin Approx. 290 g (Connector model) Approx. 330 g (Terminal block model) Head: Metal Approx. 370 g (Connector model) Approx. 410 g (Terminal block model) |