D4NL

• Selectable Operation Key insertion direction and adjustable mounting ensure installation flexibility.

• Built-in switches with multiple-contact construction are available.

• Key holding force of 1,300 N minimum.

• Can be used for either standard loads or microloads.

• Lineup includes models with a conduit outlet of M20.

• IP67 degree of protection.

• Variety of Metallic Heads Available.

Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
• Low Voltage Directive
• EN ISO 14119
• EN60947-5-1

Certified Standards

Standard type

 

Certification body Standard File No.
TÜV SÜD EN60947-5-1
(certified direct opening)
Consult your OMRON representative for details.
UL *1 UL508, CSA C22.2 No.14 E76675
CQC (CCC) GB/T 14048.5 Consult your OMRON representative for details.
KOSHA *2 EN60947-5-1 Consult your OMRON representative for details.

 

*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.

Metallic release key type

 

Certification body Standard File No.
TÜV SÜD EN60947-5-1
(certified direct opening)
Consult your OMRON representative for details.
KOSHA EN60947-5-1 Consult your OMRON representative for details.

 

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T 14048.5)

 

Utilization category AC-15 DC-13
Rated operating current (Ie) 3 A 0.27 A
Rated operating voltage (Ue) 240 V 250 V

 

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built
into the Switch.

 

UL/CSA (UL508, CSA C22.2 No. 14)

A300

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
240 VAC 30 3

 

Q300

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
125 VDC 2.5 A 0.55 0.55 69 69
250 VDC 0.27 0.27

 

Solenoid Coil Characteristics

 

Type 24 VDC 110 VAC
Rated operating voltage (100% ED) 24 VDC +10%, -15% 110 VAC ±10%
Current consumption Approx. 200 mA Approx. 50 mA
Insulation Class Class B (130°C max.)

 

Indicator Characteristics

 

Type LED
Rated voltage 10 to 115 VAC/VDC
Current leakage Approx. 1 mA
Color (LED) Orange

 

Characteristics

 

Interlock type Type 2 (EN ISO 14119)
Coding level Low level coded (EN ISO 14119)
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3
Operating speed 0.05 to 0.5 m/s
Operating frequency 30 operations/minute max.
Direct opening force *4 60 N min. (EN60947-5-1)
Direct opening travel *4 10 mm min. (EN60947-5-1)
Holding force (Fzh) *5 1,300 N min.
Contact resistance 25 mΩ max. (per contact)
Minimum applicable load *6 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui) 300 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation) 1357_sp_8_1
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage (Uimp)
(EN60947-5-1)
Between terminals of same
polarity
2.5 kV
Between terminals of different
polarity
4 kV
Between each terminal and
non-current carrying metallic
parts
6 kV
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact gap 2 × 2 mm min.
Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude
Shock resistance Destruction 1,000 m/s2 min.
Malfunction 100 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional free air thermal current (Ith) 10 A (EN60947-5-1)
Ambient operating temperature -10 to 55°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 370 g (D4NL-1AFA-B)