D4BL

• Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure.

• Die-cast aluminum body incorporating a switch box with degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.

• Equipped with a horizontal and vertical conduit outlet.

• Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key for a swinging door are available.

• The mounting direction of the head can be changed to allow the Operation Key to be inserted from four directions.

Standards and EC Directives

Conforms to the following EC Directives:

・ Machinery Directive
・ EN ISO 14119
・ EN 60204-1

Certified Standards

 

Certification body Standard File No.
TÜV Rheinland EN60947-5-1 (certified direct opening)
GS-ET-19
Consult your OMRON representative for details.
UL UL508 E76675
CSA CSA C22.2, No.14 LR45746
CQC (CCC) GB/T 14048.5 Consult your OMRON representative for details.

 

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB/T 14048.5)

 

Type Standard model Indicator model
Utilization category AC-15 AC-15
Rated operating current (Ie) 3 A 6 A
Rated operating voltage (Ue) 250 V 115 V

 

Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)

A300

 

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
10 A 60
30
6
3
7,200 720

 

Note: The UL/CSA certified rating for products with indicators (-A) is 6 A/115 VAC.

Characteristics

 

Interlock type Type 2 (EN ISO 14119)
Coding level Low Level coded (EN ISO 14119)
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. (10 A resistive load at 250 VAC)
Operating speed 0.05 to 0.5 m/s
Operating frequency 30 operations/minute max.
Direct opening force *3 19.61 N min. (EN60947-5-1)
Direct opening travel *3 20 mm min. (EN60947-5-1)
Holding force (Fzh) 700 N min. (GS-ET-19)
Contact resistance 50 mΩ max.
Rated insulation voltage (Ui) 300 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class I (with ground terminal)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage (Uimp)
(EN60947-5-1)
Between terminals of same
polarity
4 kV
Between terminals of
different polarity
Between each terminal and
ground
Between solenoid and ground 2.5 kV
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact gap 2 × 2 mm min.
Vibration resistance Malfunction 10 to 55 Hz, 0.35 mm single amplitude
Shock resistance Destruction 1,000 m/s2 min.
Malfunction 300 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 10 A (EN60947-5-1)
Ambient operating temperature -10 to 55°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 800 g